Laserfiche WebLink
i r ._ ._ �I <br /> . Manual S Compliance Report Job: 2600BsfADS <br /> Date: 6113/2017 <br /> Enfire House By: Dave - <br /> � Bayonet Plumbing Heating and Air <br /> ' s - • • <br /> For: Lennar Homes . <br /> • • • • e <br /> Design Conditions <br /> Outdoor design DB. 91.3°F Sensible gain: 33514 Btuh Entering coil DB 75.6�F <br /> Outdoor design WB: 77 3°F Latent gain: 3601 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 37115 Btuh <br /> Indoor RH. 50% Estimated airflow: 1400 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR <br /> Actual airtlow: 1400 cfm <br /> Sensible capacity: 35700 Btuh 107% of load <br /> Latent capacity� 6300 Btuh 175% of load <br /> Total capacity: 42000 Btuh 113% of load SHR. 85% <br /> • e • <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss: 39282 Btuh Entering coil DB� 69.7°F <br /> Indoor design DB� 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-042-230-21+CBA27UHE-042-230*++TDR <br /> Actual airflow: 1400 cfm � <br /> Output capacity: 42000 Btuh 107% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip . <br /> Manufacturer n/a Model: n/a+n/a <br /> Actual airflow: 1400 cfm <br /> Output capacity� 0 kW 0% of load _ Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft'� 2017-Jun-1313:32:40 <br /> ��� 9 Right-SuRe�1 Universal 2017 17.0.23 RSU05714 Page 1 <br /> .th CBA27UHE AH's12600B sf ADS drawn 3.5 ton.rup Calc=MJS Front Door faces: N <br />