Laserfiche WebLink
, �- S <br /> � FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2386B sf ADS Builder Name: Lennar Homes <br /> street: 36034 Stable Wil�Avenue Pem,�t otece: City of Zephyrhills <br /> City,State,Zip. ,FL, Permit Number e�7OS <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ftZ � <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1118.00 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ftZ <br /> 4 Number of Bedrooms 5 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1272.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1120.00 ft <br /> 6. Conditioned floor area above grade(ftz) 2389 b.Knee Wall(Vented) R=30.0 152.00 ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 <br /> 11 Ducts R ftz <br /> 7. Windows(168.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 477.8 <br />' a. U-Factor Dbl,U=0.54 96.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 38.68 ft� 12.Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 42.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ftZ <br />� SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth. 1 198 ft. <br /> Area Weighted Average SHGC: 0.305 14 Hot water systems <br /> 8. Floor Types (2389.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ft� None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> I Total Proposed Modified Loads. 71.80 <br /> Glass/Floor Area. 0 070 - PASS <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��:'��Sr9�.�, <br /> this calculation are in compliance with the Florida Energy specifications covered by this �'w , �.� .;�.;, 0,�,, <br /> Code. calculation indicates compliance ��r,;,°'� `_=:�'�° � <br /> with the Florida Energy Code. +�+ �t+d�u•� ` � ��' "����� <br /> �'�,:, - � O. <br /> /✓ /. �r ;;`.•,` ',.:;;;:+'�_, *� <br /> PREPARED BY: �av� �Wl�'1�Y1 Before construction is completed ,r��, � -• <br /> DATE: this building will be inspected for � "i`���j. - � <br /> _ compliance with Section 553.908 * �'�_ � �� �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �^�, ,,;�s� ��. <br /> with the Florida Energy Code. ��D yyE'�� <br /> OWNER/AGENT BUILDING O CIAL: <br /> , DATE: DATE: �" - <br /> - Compliance requires certification the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than O.U40 Qn for whole house. <br /> 7/6/2017 7:58 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />