My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18705
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18705
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2018 9:03:53 AM
Creation date
7/27/2018 9:03:52 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18705
Building Department - Name
LENNAR HOMES INC
Address
36034 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l 3 . <br /> � FORM R405-2014 . <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDIIVG CONSTRUCTIOI� <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 2386B sf ADS Builder Name: Lennar Homes <br /> street: 36034 Stable Wi1k Avenue Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2570.5 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.70 ft' <br /> b.Concrete Block-Int Insul,Exterior R=4 1 1118.00 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 166.83 ft2 <br /> 4 Number of Bedrooms 5 d.N/A R= ft? <br /> 10.Ceiling Types (1272.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1120.00 ftz <br /> 6. Eonditioned floor area above grade(ft2) 2389 b.Knee Wall(Vented) R=30.0 152.00 ftZ <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11 Ducts R ftZ <br /> 7. Windows(168.0 sqft.) Description Area a.Sup.Attic,Ret:2nd Floor,AH.2nd Floor 6 477.8 <br /> a. U-Factor Dbl,U=0.54 96.00 ft2 <br /> - SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 38.68 ftZ 12.Cooling systems kBtu/hr Effciency <br /> SHGC: SHGC=0.28 a.Central Unit 42.0 SEEF2:15.00 <br /> c. U-Factor Dbl,U=0.56 33.33 ft� <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftz a.Electric Heat Pump 42.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1 198 ft. <br /> � Area Weighted Average SHGC: 0.305 14 Hot water systems <br /> 8. Floor Types (2389.0 sqft.) Insulation Area . a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1269.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 1120.00 ft2 None , <br /> c.N/A R= ft2 15.Credits Pstat <br /> Total Proposed Modified Loads. 71.80 pASS <br /> Glass/Floor Area: 0.070 <br /> Total Baseline Loads: 72.83 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ,��•'��T��� <br /> this calculation are in compliance with the Florida Energy specifications covered by this 'v°,L�� 'A 4� t7t7; <br /> Code. calculation indicates compliance ��',,�, rT', =-e+`*+�,�'!¢'� <br /> /' with the Florida Energy Code. `` �� � � <br /> � trtrri _��,,,,r`,-:;�'��"'`,�iti ,� <br /> PREPARED BY' �QV� �����'c Before construction is completed � ,.;* " d <br /> DATE: this building will be inspected for Lry `�?:�'� �.: <br /> compliance with Section 553.908 * <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �,,�,, ���. <br /> with the Florida Energy Code. , �'�.�tN�`� _ <br /> OWNER/AGENT: BUILDING OFF IAL. <br /> DATE: DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403:2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,.is not greater than 0.040 Qn for whole house. <br /> 7/6/2017 7:58 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.