Laserfiche WebLink
� •. � •. <br /> SILENT 5104B Fire Control <br /> KNIGHT` Communicator <br /> 0 <br /> by Honeywell <br /> The speed, reliability and value <br /> of digital communications from <br /> the company you can trust <br /> As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B <br /> Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. <br /> This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble <br /> conditions. It transmits via ordinary phone lines—eliminating the need for expensive leased line arrangements. <br /> Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? <br /> Go with the industry standard—the 5104B Fire Control Communicator from Silent Knight. <br /> For more information, please call 1-800-328-0103. <br /> Model 5104B the central station. If one of the <br /> Fire Control Communicator telephone lines faults for more than – r <br /> The Silent Knight Model 5104B is a 60 seconds, it will automatically •�""""` <br /> six-zone fire control communicator switch to the other to report the �� " <br /> providing digital fire reporting over failure. <br /> ordinary telephone lines, The communicator will signal <br /> eliminating the need for costly activation, restoration and trouble �-^-�,' <br /> leased lines. IYs UL 864 and NFPA conditions on any of six inputs. If ,,. �:n..�,a <br /> ��;� a,�.oabi <br /> 72 approved for monitoring local an application requires a different :�r; �' <br /> ;:;:. <br /> evacuation controls. input configuration, the individual ; <br /> As a stand-alone unit, it can be input styles may be changed by Model 5'104B <br /> used to monitor: using a Model 7181 Fire Zone <br /> • Sprinkler systems for waterflow, Converter Module. The 7181 also <br /> supervisory, and gate valve allows use of two-wire type smoke . Dual phone line inter�ace Automatic <br /> tamper conditions. detectors, instead of the normal self tests every 24 hours with report <br /> four-wire contact type, for sent to central station. <br /> • Automatic fire detection systems automatic fire detection • Reports in SIA and most major <br /> for structures that are not applications. communications formats. <br /> required to have a fire alarm <br /> system but want property Features • 60 hours of standby power. <br /> protection (e.g. to call the fire • UL 864 Listed as an NFPA 72 • Operates on loop start phone lines <br /> department after hours). <br /> Central Station or Remote Station ahead of the building PBX system <br /> • Monitors dry contact alarms, protected premise unit. • A single, programmable output is <br /> • FM a roved provided for alarm or dialer failed <br /> trouble and supervisory outputs, Pp conditions (cannot be used for <br /> then transmlts a separate code ' Can be used as a stand-alone or as evacuation purposes). <br /> for each a add-on DACT. <br /> The Model 5104B is fully • Six fully supervised inputs:one <br /> Class A(Style D) input, and five <br /> supervised. Its microprocessor Class B (Style A) inputs. <br /> constantly runs programs to . Downloadable for remote <br /> monitor AC, standby battery, zone programming. <br /> inputs and telephone line • Fuseless overload protection with <br /> connections. If a fault condition is automatic reset circuitry and fault <br /> detected, it sounds a local trouble indicators—eliminates the cause of <br /> audible and reports the condition to most field calls <br /> I <br />