Laserfiche WebLink
.. s II <br /> FORM R405-2014 <br /> • � , I <br /> i <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION � <br /> Florida De artment of Business and Professional Re ulation - Residential Performance Method <br /> p 9. I <br /> � <br /> I <br /> Project Name: 3127B sf ADS Builder Name: LENNAR HOMES � <br /> screet: 6503 Paden Wheel Street Permit otfce: City of Zephyrhills ; <br /> City,State,Zip: ,FL, Pertnit Number: <br /> i <br /> Owner• LENNAR HOMES Jurisdiction: 611000 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) , <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ � <br /> 4. Number of Bedrooms 5 d.N/A R= ft' <br /> 5, is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) insulation Area 2 <br /> a.Under Attic(Vented) R=30.0 1772.00 ft � <br /> 6. Conditioned floor area above grade(ft2) 3127 b.Knee Wall(Vented) R=30.0 174 00 ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft' <br /> 11 Ducts R ft2 <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 302.4 <br /> a. U-Factor• Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 ' <br /> b. U-Factor Dbl,U=0.56 117.00 ft' 12.Cooling systems kBtu/hr Efficiency ; <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 � <br /> c. U-Factor Dbl,U=0.56 86.67 ft' <br /> SHGC: SHGC=0.32 13.Heating systems � kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 i <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 , <br /> Area Weighted Average Overhang Depth. 4.220 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems ! <br /> a. Electric Cap:40 gallons <br /> 8. Floor Types (3181.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftz b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ft' None <br /> c.other(see details) R= 260.00 ft= 15.Credits Pstat <br /> Totai Proposed Modified Loads: 90.98 <br /> Glass/Floor Area: 0.117 PASS <br /> Total Baseline Loads: 92.81 <br /> � . <br /> I hereb certi that the lans and s ecifications covered b Review of the lans and 'C�:�T � � <br /> Y fY P P Y P p4: _ �?,�., <br /> this calculation are in compliance with the Florida Energy specifications covered by this °�,. ,� � _ � p�, <br /> Code. calculation indicates compliance �,j'�v, � ��;,��•` +� , <br /> ,{/,,� /. with the Florida Ener Code. �' jrrrr,�:'���..;:_��'•'''��`;�{O . <br /> ���Qi Wl 9Y �' .: ' :�`'�::+�. .'� <br /> PREPARED BY. r[ ���'c Before construction is completed w &-- ", , " .- <br /> DATE: this building will be inspected for s�,ry '"��`'" � . <br /> �N��i ' <br /> compliance with Section 553.908 * .�'-�'- '� ;, � <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,i,�- . � ��•q. : <br /> with the Florida Energy Code. �D H*E.'T� � <br /> �� I <br /> OWNER/AGENT. BUILDING OFFICIAL., `-Z���"` � <br /> DATE: - DATE. '%'_�r �'1 I , <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certifed factory-sealed in accordance with R403.2.2.1. I <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, � <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. � <br /> 7/10/2017 12:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 ' <br />