Laserfiche WebLink
FORM R405-2014 <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Below <br /> 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ftz 0 0 0.6 0 <br /> 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 <br /> _ 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 <br /> 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft' 0 0 0.6 0 <br /> 5 S=>SW Exterior Concrete Block-Int Insul cafe 4 1 13 6 8 0 108.0 ftZ 0 0 0.6 0 <br /> 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ftz 0 0 0.6 0 <br /> 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 <br /> 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ftZ 0 0 0.6 0 <br /> 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ftZ 0 0 0.6 0 <br /> 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ftZ 0 0 0.6 0 <br /> 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ftZ 0 0 0.6 0 <br /> _12 W=>NW Euterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ftZ 0 0 0.6 0 <br /> _13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0 <br /> _14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ftZ 0 0 0.6 0 <br /> _15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84 0 ftZ 0 0 0.6 0 <br /> 16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0 <br /> _17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 <br /> _18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ftZ 0 0.25 0.01 0 <br /> _19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ftZ 0 0 0.6 0 <br />� _20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ftZ 0 0 0.6 0 <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 416ftz 416ftz 43.7ft 8ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2819 7 <br /> ' HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump Split HSPF:8.5 32.8 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1 <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />