Laserfiche WebLink
� •f � . <br /> Manual S Com liance Re ort Job: 1941AsfADS <br /> p p Date: 7/1412017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • � <br /> For: Lennar Homes <br /> • • • . . <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 26239 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 4271 Btuh Entering coil WB. 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 30510 Btuh <br /> Indoor RH 50% Estimated airflow: 1200 cfm <br /> I <br /> Manufacturer's Performance Data at Actual D.esign Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR <br /> Actual airflow� 1200 cfm <br /> Sensible capacity: 29070 Btuh 111% of load <br /> Latent capacity: 5130 Btuh 120% of load <br /> Total capacity: 34200 Btuh 112% of load SHR: 85% <br />' � • • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 28628 Btuh Entering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR <br /> Actual airflow� 1200 cfm <br /> Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip � <br /> Manufacturer: n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity: 0 kW 0°/a of load Temp. rise: 0 °F <br /> Meets are all requirements of ACCA Manual S. <br /> .� WI'1 htsoft° 2017-Ju1-14 09:22:59 <br /> �� 9 Right-SuiteQ�l Universal 2017 17.0.23 RSU05714 Page 1 <br /> �'� ...h CBA27UHE AH's\1941A sf ADS drawn 3ton.--up.rup Calc=MJ8 Front Door faces: S <br />