Laserfiche WebLink
Single Family Dvvelling <br /> P1an Revzew Comments <br /> 1. F.F.E, shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lats shall be graded to con�p2y with R4Q1.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. AlI property markers shall be uncovered and marked at tzme af first inspection. <br /> 8. All A.D.A. requirements sha11 be met. <br /> 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. AlI Garages shall comply with sectian R302.6 of the F.B.C. {Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters sha11 comply with section P607.3 of the F.B.C. <br /> 13. Foundatiorz supports forAl�units shall be raised at least 3"above finished grade. M1308.1 <br /> 14. Return air in all bedroarns. F.B.C. M1620.4 <br /> 15. Smake detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R3Q8.4 of the F.B.C. <br /> 17. Al1 means of egress are to be in aceordance with R31 I of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in shawers or tubs. R702.4.2 F.B.C. <br /> I9. Combination-type AFCI breakers are required at a11 Iocatians requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new canstruction that uses fossil-burning heating <br /> ar appliances or an attached garage. They sha11 be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit ta unit. This includes all <br /> undergraund plumbing and electric. <br /> 22. A112008 N.E.C. Codes will be enfarced. <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2408 N.E.0 <br /> 22. In accardance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the struct�zre. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 5�'Edition <br /> R.O.W.-Right of VVay <br /> A.D.A.-Americans with Disabilities Act N.E.C.-Natianal Electric Code(2008) <br />