Laserfiche WebLink
Sin le Famil Dwellin � <br /> � Y g <br /> Plan Review Gomments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and az1 engineered site plan. <br /> 2. Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk sha11 have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. AII property markers shall be uncovered and marked at time of first inspection. <br /> 8. All A.D.A. requirements shall be znet. <br /> 9. Na electric,plumbing,mechanical, or framing sha1l be covered without an inspectian and <br /> appraval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. {Fire Separatian}. <br /> 11. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. IVI303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports far A/C units sha11 be raised at least 3"above fnished grade. M130$.1 <br /> 14. Return air in all bedroorns. F.B.C. M1620.4 <br /> 15. Smoke detectors are ta be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 ofthe F.B.C. <br /> I7. AlI means of egress are ta be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combinatian-type AFCI breakers are required at all Iocations requiring an AFCI type breaker. <br /> 20. Carban monoxide alarms will be required in new construction that uses fossil-burning heating <br /> ar appliances or an attached garage. They sha11 be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical sha11 be separate from unit to unit. This includes a11 <br /> underground ptumbing and electrie. <br /> 22. A112008 N.E.C. Codes will be enforced. <br /> 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 22. In accardance with the Land Development Cade, lots shall be sodded before final at least 10 <br /> feet around the shzzcture. <br /> F.F.E.-Finished F1aor Elevation <br /> F.B.C-Florida Building Code 5�'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008) <br />