MAJESTIC OAKS
Building Department - Doc Type
Permit
Permit #
17-18805
Building Department - Name
NHC-FL115 LLC
Address
39525 CHARIOT LN LOT 229
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. • r. <br /> Once the ground anchor assembly is fully installed,attach longitudinal and lateral struts according to the diagram under anchor assembly placement(page 1.). The <br /> I�teral arm.fasteners are to be installed tightly(nuts and bolts). The eeam Clamp assembly has two holes for the bolt and nut placement. Depending on the width of <br /> the beam,the corresponding hole should be used that pushes the front of the metal plate as close as possible to the upright of the beam. See the illustration on page <br /> 2,#5. <br /> Lateral struts should be installed in line with the center anchor head and attached at the top of the I-beam. <br /> Lateral strut angles must fall within 10 degree minimum-60 degree maximum. Longitudinal strut angles must fall within 10 degree minimum-50 degree maximum. <br />, Longitudinal Strut longitud3nal Strut <br /> qttached Point Atiached Point <br />' facing the home IEFT CORNER Frcing th�homc BiGHT CORNF,P <br /> 1 <br /> �,I 1 � <br /> � <br /> ��f � � <br /> J,N'J <br /> I:ateral5trut lateral Stmt <br /> l,ttached Point Attached Point <br /> \ <br /> Sidewall Sfwp Sidexell Strap <br /> Cornection � Connectian <br /> I After the Lock Down Anchor Assemblies have been fully installed and all permiter anchors and straps fully installed and tightened—each strut has 4 self tapping <br /> screws that must be installed as the final step. Predrilled holes are provided on the outer strut indicating placement. If the predrilled holes can not be accessed, <br /> install the screws as close to the predrilled holes as possible-making sure they are tapping into the inner strut. � <br /> The Lock Down Anchoring System should only be used for homes in the state of Florida. This anchoring system is not designed,tested or approved for use in any <br />, other state. <br /> Contact Home Pride Inc.276-466-0502 or at contactusC�hpanchors.com for any questions concering this product. <br /> Legacy Engineering listing#113 <br /> Notes: <br /> PRODUCT WARRANTY <br /> Home Pride warrants its Lock Down Anchor System(HP LDS)against defects in workmanship and material at the site of its initial installation.The HP LDS is specifically <br /> designed and approved for use in the State of Florida. This praduct is not approved for use and shouid not be used outside the State of Florida. This product must <br /> not be reused or reinstalled at any other location. If used in violation of this Warrenty or not installed in accordance with installation instructions,all written and <br /> implied warranties are void and disclaimed. HP LDS products which are found to have defects will be replaced or repaired at Home Pride's option.This Express Warrenty <br /> is limited to replacement of product only and does not cover any labor or installations costs. When the product is replaced,all Warranty rights are extinguished.This <br /> Warrenty is only to the benefit of the original purchaser and is not trensferable. � <br /> There are no other warranties(express or implied)whatsoever which apply to the HP LDS product or to items that are functionally part of the HP LDS produd. Home <br /> Pride disclaims any and all other implied warranties,including(but not limited to)warranties of habitability,workmanship,materials and fitness for a particular purpose <br /> to the extent allowed by law and any implied warranty that exists despite this disclaimer is limited to a period of one(1)year from the effective date of this Warranty <br /> These IimiYations shall be enforceable to the extent permitted by law. <br /> HP LDS products which are examined and are found not to be defective will be returned to user and all costs associated with examination of the anchor product will be <br /> incurred by the user The user is responsible for all maintenance of the HP LDS product including regular monitoring of stability and integrity of HP LDS products. , <br /> For a warranty claim,contact your distributor or Home Pride Inc.at 15100 Industrial Park Road,Bristol,Virginia,24202. <br /> i <br /> 3. NOME�PRIDE , � <br /> _......_-----------._._....— � <br /> � <br />