Laserfiche WebLink
t <br /> *' <br /> � <br /> SEE DEfAIL 3„ 6" 6� � � <br /> "E" SHT 2 <br /> -� 3� s�. L � 3^�J 3� � 3n �3i O ¢(D <br /> I I <br /> � � I I I I I �s_ fin� I I I I 0 �� <br /> 6" 6' <br /> 6" Q (�Q <br /> N � O � � �¢ <br /> � M N � � � Q U <br /> Mr p a Z �� <br /> a SEE DEfAIL < � �U <br /> N „D" SHT 2 � Z �� <br /> f� <br /> � � � � � <br /> SEE DEfAIL � w p <br /> "C" SHT. 2 A w i,, B <br /> . � in <br /> o � <br /> A � A a � � G H B � <br /> g" — — � W <br /> �.� � <br /> s' � � o <br /> L6„ � � � g�� Joa <br /> I � � � � � � � � � � � �L7�ly w �o <br /> �ffi NN ��S <br /> 6 = <br /> 3" 3p 3.�f 3„6 6� 3n �3�� U �� � o <br /> —I <br /> SEE DEfAIL g^ 6^ o e o �d <br /> 'F" SHT 2 g^ � c� <br /> a a <br /> HARDWARE SCHEDULE <br /> � <br /> 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND m <br /> SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED <br /> AT 5-1/2" CENTERLINE. <br /> ATTACHMENT DETAIL �MyN^ 2. 4'� X 4" FULL MORTISE BUTT HINGES. <br /> o�, t. . _0.25" <br /> 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, Mnx i`x�/2 CORRUGATED piox2" woo� scREw <br /> SIGNED AND SEALED BY ROBERTO LOMAS, PE SHIM 3" F�zoM EACH END 6 FROM FACH END cn <br /> AND 7" OC AND 12" OC <br /> (FLORIDA #62514) WITH THE LOWEST (LEAST) c�—I I— . � � <br /> FASTENER RATING FROM THE DIFFERENT FASTENERS �: � <br /> BEING CONSIDERED FOR USE. JAMB, HEAD, AND '?'�. A`C�RT�LI�C � <br /> THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE CAULK <br /> #10 WOOD SCREWS OR 1/4" TAPCONS. A PHYSICAL TYPICAL MASONRY ACRYLIC <br /> SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR ANCHOR INSTALLATION cau� I c� � <br /> LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". � o <br /> WOOD SCREW EDGE DISTANCE MIN 3/4". , . .. <br /> o', t. COMBINATION WOOD COMBINATION WOOD <br /> 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM i.5o"� MULLION (BOXED) MULLION (BOXED) <br /> ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT MIN _ �p,�" (3 �Jioxz—�/2" � � <br /> OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE SHIM �o6D SCREWS z <br /> MINIMUM EMBEDMENT OF 1-1/4��. I EACH END p��endunmNAMI <br /> CL— �— a�: 5 26 17 <br /> 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO �j � cerMrcatbnNo. or3 v sc�: N.T.S. <br /> TRANSFER LOADS TO STRUCTURE. ��ey' ' owc.ar: SWS <br /> Date Review ' 7- <br /> 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. � � CHK.BY: <br /> IYPICAL WOOD BUCK <br /> ANCHOR INSTALLATION DRAN7NG ND.: <br /> INTEGRAL WOOD DWG-MA-FL0214-17 <br /> MULLION (CHS) sH�r 3 oF 3 <br />