My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18835
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18835
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2018 11:17:46 AM
Creation date
7/30/2018 11:17:44 AM
Metadata
Fields
Template:
Building Department
Company Name
PAKHILL
Building Department - Doc Type
Permit
Permit #
17-18835
Building Department - Name
MASHBURN,MONTGOMERY L
Address
38831 NORTH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �� <br /> - 1 I1�1`d'��ER,� <br /> � <br /> 4.3 Accessorv Starter Strips: <br /> 4.3.1 Pro-Start� Eave/Rake Starter Strip Shingles and WeatherBlocker'"' Premium Eave/Rake Starter Strip Shingles <br /> are starter strips for asphal,t roof shingles. <br /> 4.3.2 quickStart� Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS <br /> modified bitumen starter strip, nominal 9-inch x 33 ft roll,for use with asphalt shingles with exposure of 6- ' <br /> inch orless. � <br /> 4.3.3 StarterMatchT"^ Sharter Strip Sfiingles are color-coordinated starter strips for use with Grand Canyon° and II� <br /> Grand Sequoia° series asphalt shingles. StarterMatchTM are installed as the second starter for Grand '� <br /> Canyon�and Grand Sequola'�series installatians. ' <br /> 5. LIMITATIONS: . <br /> 5.1 This is a bUilding code evaluation. Neither T�in'ity�ERD nor Robert Nieminen, P.E. are, in any inray, the <br /> Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was <br /> used for permitting or design guidance unless retained specifically for that purpose. <br /> 5.2 This Evaluation Report is not for use in the HVHZ. <br /> 5.3 Fire .Classification is not part of this Evaluation Rep.ort; refer to current Approved Roofing Materials <br /> Directory for fi�e ratirigs of this product. <br />� 5_G Wind Classification: <br /> 5.4.1 The GAF asphalt sh'ingles noted in Section 4.1 are Classified in accordance with FBC Ta61es 1507.2.7.1 and <br /> R90S�2.6,1 to ASTM D316�., Class F �nd/ar ASTM p715$, Class H, indicating f�e shingles are�aceptable for <br /> use in all wind zones up to V�d=15Q mph(VUit=194 mph). Refer to Section 6 for installation requirements <br /> to meet this wind rating. <br /> 5.4.2 The GAF hip &ridge shingles noted in Sectlon 4.2 are Classified In acc�rdance with FBC Tables 1507.2.7.1 <br /> and R905.Z,6.1 to ASTM D3�.51,Class F,indicating the shingles are acceptable for use in all wind zones up to <br /> Vasd=150.mph(V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating, <br /> 5.4.3 ClassificatiQn by ASTM D7158 applies only to exposure category e qr C, as defined !n FBC 160�.4.3, and a <br /> mean roof height of 60 feet 6r less. Calculations l�y a qualified design professional are required for <br /> conditions outside these limitations, Contact the shirigle manufacturer for.data specific to each shingle. <br /> 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building <br /> C�de and F.A.C. Rule 61G20-3. <br /> 6. I NSTALLATI ON: <br /> 6.1 Underlayment: <br /> 6.1.1 Underlayment shall be acceptable to GAF and shall holcl eurrent Florida Statewide Product Approval, or be <br /> Locally Ap�roved per Rule 61G20-3,per FBC 5ections 1507.2.3,15Q7.2.4 or R905,2.3. <br /> 6.2 5tarter Sfiingles or'Starter Strip: <br /> 6.2.1 Installatioq of Pro-Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium �ave/Rake Starter Strip <br /> Shingles and QuickStart Peel &Stick Starter Roll shall comply with the GAF current published instructions. <br /> 6.3 Asphalt Shingles: <br /> 6.3.1 Installation of asphalt shingles shall comply with the.manufacturer's current published instructions, using <br /> minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905:2, with the following <br /> exceptions: <br /> ➢ Camelot, Camelot II, Grand Canyon,.Grand 5equoia, Grand.Sequoia lR, Grand Sequoia ArmorShield, and <br /> Woodland require minimum five(5)nails per shingle. <br /> > Slateline requires mitiirrium six(6)nalls per shingle. <br /> Exterior Research and Design,LLC. Evaluation Report 01506,01.08-R21 <br /> Certificate ofAuthorizatlon a9503 FL1D124-R19 <br /> Revision 21:08/26/2016 <br /> Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.