My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18877
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18877
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:30:03 AM
Creation date
7/31/2018 11:30:01 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18877
Building Department - Name
LENNAR HOMES LLC
Address
3185 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. . <br /> . , � � <br /> � ; <br /> ' I <br /> Manual S Compliance Report Job: 2575Bsf ADS ; <br /> Date: 8/14/2017 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> . � <br /> ' • - � • <br />� For Lennar Homes <br /> O i � 0 • i <br /> Design Conditions <br /> Outdoor design DB 91.3°F Sensible gain: 18450 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB� 77.3°F Latent gain: 3541 Btuh Entering coil WB. 62.8�F � <br /> Indoor design DB: 75.0°F Total gain: 21991 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm ' <br /> � <br /> Manufacturers Pertormance Data atActual Design Conditions <br />� Equipment type: SpIitASHP <br /> Manufacturer� Lennox Model: 14HPX-024230-21+CBA27UHE-024230*++TDR <br /> Actual airflow� 800 cfm � <br /> Sensible capacity: 21420 Btuh 116% of load <br /> Latent capacity: 3780 Btuh 107% of load ! <br /> Total capacity� 25200 Btuh 115% of load SHR. 85% <br /> j <br /> 4 <br /> o e • � <br /> I <br /> Design Conditions '; <br /> Outdoor design DB: 30.8°F Heat loss 12825 Btuh Entering coil DB 69.6°F <br /> Indoor design DB: 70.0°F <br /> I <br /> Manufacturer's Performance Data atActual Design Conditions ; <br /> Equipment type: SpIitASHP � <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230'`++TDR <br /> Actual airtlow: 800 cfm , <br />' Output capacity: 21800 Btuh 170% of load Capacity balance: 17 °F ! <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F I <br /> Backup equipment type: Elec strip <br /> Manufacturer Model: I <br /> Actual airflow: 800 cfm I <br /> Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F ; <br /> . � <br /> Meets are all requirements of ACCA Manual S. <br /> .� wri htsoft°� 2017-Aug-14 11:39:23 � <br /> ��� g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 2 <br /> ..A27UHE AH's\25756 sf ADS template 1.52 ton.rup Calc=MJS Front Door faces:SE <br />
The URL can be used to link to this page
Your browser does not support the video tag.