Laserfiche WebLink
� � <br /> � . i <br /> FORM R405-2014� <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes 003 <br /> street: Mottlden Hollow Drive Perm�t o�ce: City of Zephryhills <br /> City,State,Zip: ,FL, Pertnit Number <br /> owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz <br />, b.Frame-Wood,Adjacent R=11.0 506.78 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d•N�p` R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area z <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rtn,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl, U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft� 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft= a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems I <br />� a.Electric Cap:40 gallons <br /> S. FloorTypes (1936.0 sqft.) Insulation Area EF 0.950 I <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft� b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= �z 15.Credits Pstat � <br /> Total Proposed Modified Loads. 62.94 pASS <br /> Glass/Floor Area: 0.081 Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 4'Ck�;ST��,' '� <br /> O � - <br /> this calculation are in compliance with the Florida Energy specifications covered by this .�' �� �_��p� ', � <br /> Code. calculation indicates compliance -��l;,;''� ==-s a;.���•,,�s+�, .; <br /> ,I with the Florida Energy Code. F+ nrrr,�°?%•;,;=�.`;,•+`^�'„"O <br /> PREPARED BY: �aVe �����'` Before construction is completed :r� .� . "`.'. " � <br /> DATE: this building will be inspected for � `�`1�a ` - ' `-�� <br /> � �'� � <br /> compliance with Section 553.908 ' *=. .�`� - = •* � <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. -_ �, j <br /> Y fY 9, 9 P "r�r - , g, <br /> with the Florida Energy Code. , 'G'OD'y�;�R�,. <br /> OWNER/AGENT. BUILDING OFFICIAL: � <br /> DATE: DATE: - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage ; <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:24 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 � <br /> I <br />