My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18879
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18879
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:33:04 AM
Creation date
7/31/2018 11:33:02 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18879
Building Department - Name
LENNAR HOMES LLC
Address
3161 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� i • <br /> , ' , . <br /> FORM R405-2014 I <br /> WALLS � <br /> Adjacent SPa� Cavity Width Height Sheathing Framing Solar Below <br /> 0 <br /> 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 <br /> _2 N=>NE Garage Frame-Wood Main 11 20 ,8 8 165.3 ft� 0 0.01 0 ! <br /> _ 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ftZ 0 0.01 _ 0 <br /> 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 <br /> 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft� 0 0.60000Q 0 <br /> 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ftZ 0 0.600000 0 <br /> 7 S=>SW Exterior Concrete Block-Int Insul Main 4:0999 6 8 48.0 ft' 0 0.600000 0 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation � <br /> 1 427 ft2 427 ft' 42 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) 000356 1695.9 93.1 175.09 .2669 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 26 kBtu/hr 1 sys#1 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts <br /> 1 Central Unit Split SEER: 15 30 kBtu/hr 900 cfm 0.85 1 sys#1 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None ft� <br /> DUCTS <br /> / —Supply— —Retum— Air CFM 25 CFM25 HVAC# <br /> V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 j <br /> � <br /> , <br /> 7/14/2017 9:12 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.