My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18879
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18879
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:33:04 AM
Creation date
7/31/2018 11:33:02 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18879
Building Department - Name
LENNAR HOMES LLC
Address
3161 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L f � <br /> FORM R405-2014 , <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method ' <br /> � <br /> Project Name: 1791A sf ADS Builder Name: Lennar Homes 0039 � <br /> street: Moulden Hollow Drive Permit Office: <br /> Ciry,State ZIp� 1 ,Fl., Permit Number��.o�phyrhills _ <br /> Owner• Lennar Homes Jurisdiction:(j 1 OO <br /> Design Location. FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4 1 1241.30 ft2 ! <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ft2 _ <br /> 3. Number of units,if multiple family 1 c.N/A R- ft= <br /> 4 Number of Bedrooms 4 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1817.00 ftZ <br /> 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ft' <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ftZ <br /> 11 Ducts R ft' <br /> 7. Windows(143.3 sqft.) Description Area a.Sup.Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor• Dbl,U=0.54 87.00 ftz <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 33.33 ftZ 12.Cooling systems k6tu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 _ <br /> c. U-Factor Dbl,U=0.56 23.00 ftZ -- <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> � d. U-Factor• , N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14 Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1817.0 sqft.) Insulation Area EF•0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features <br /> b.N/A R= ft= None <br /> c.N/A R= � ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and '�1�:5'7' <br /> O� :.. _ .q�;� . <br /> this calculation are in compliance with the Florida Energy specifications covered by this ^�v '" �:�, C? <br /> ,���� ����,�, . <br /> Code. calculation indicates compliance ` �j��+i,; ; � .ti. •� <br /> with the Florida Energy Code. �+ trrerr�'.'�%�::;:��`�°."�",��O <br /> .�,+ `_. . . .,,,,:�.� ,n� <br /> PREPARED BY �a�e ���� Before construction is completed w •, '` .•• <br /> DATE: this buildin will be ins ected for � � ���` " � � <br /> 9 P t7 ` �1�. ; a . <br /> compliance with Section 553.908 �. �` � ' �. <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. �,� ; �.q.. <br /> with the Florida Energy Code. ,�'f.7;jj'yS,��� <br /> OWNER/AGENT. BUILDING O FICIAL: <br /> DATE: DATE: - � ' <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as � <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br /> test report in accordance with R402.4.1.2. � <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,. <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:12 AM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.