My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18881
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18881
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:35:56 AM
Creation date
7/31/2018 11:35:55 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-18881
Building Department - Name
LENNAR HOMES LLC
Address
3293 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a . � ' • <br /> Manual � Compli�nce Report �db: WHC lot 0028 Hidden riv.., <br /> Date: 811412097 <br /> Entire Hous� By: DaveAldrich ' <br /> Bayonet Plumbing Heating and Cooling <br /> 895�New York ave,Hudsan . . " <br /> o � ' � � <br /> Far: Lennar Homes <br /> • e . • . <br /> Design Conditions ` <br /> Qufdoor design DB. 93.3°F Sensible gain: 4300 Btuh Entering coiI DB� 75.5°F <br /> Outdoor design WB: ?7.3°F Latent gain: 1052 Btuh Entering coil WB. 62.8°F <br /> indoar design DB: 75.0°F Tatal gain: 5352 Btuh <br /> Indoor RH: 50% Esfimated airfiow� 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment fype: SpEit ASHP <br /> Manufacturer: Lennax Model: 14HPX-018-230A21+CBA27UHE-018-230'++TDR <br /> Actual airfiaw: 604 cfm <br /> Sensible capacity� 15300 Btuh 356% of(oad <br /> Latent capacity: 2700 Btuh 257% of load <br /> Tota(capacity: 98000 Btuh 336°l0 of laad SHR: 85°!0 <br /> • • • <br /> Design Canditions <br /> Outdoor design DB: 30.8°F Neat loss: 6149 Btuh Entering coii DB. 69.7°F <br /> Indoor design DB. 7Q.0°F <br /> Manufacturer's Perfarmance Data at Actual Design Gonditions <br /> Equipment type: Split ASHP <br /> Menufacturer� Lennox Model: 14HPX-018-230A21+CBA27UHE-018-230*++TDR � <br /> Actual airflow: 60Q cfm , <br /> Output capacity: 17500 Btuh 285% of load Capacity balance: 4.3 °F <br /> Supplemental heat required: 0 Btuh Ecanomic balance: -99 °F ! <br /> Backup equipment type: Elec strip , <br /> Manufacturer• n/a Model: Na+n/a <br /> Actual airflow: 600 cfm <br /> Outpuf capacity: 0 kW 0`Ya of laad 3emp. rise: 0 �F <br /> Meets are all requiremants of ACCA Manua]S. <br /> � wri htsoft� 20i7-Aug-14 t3:21.44 - <br /> g Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> �'�...7UHS AH's1WHC 194!sf lot o�28 Nidden river.rup Catc=MJS Hause Frant faaes: E <br />