My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18886
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18886
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:40:45 AM
Creation date
7/31/2018 11:40:02 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18886
Building Department - Name
LENNAR HOMES LLC
Address
6557 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L _ J <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 3127B sf ADS Builder Name: LENNAR HOMES <br /> screet: 6557 Silverado Ranch Boulevard Permit Office: Cl of Z�e�yrhills <br /> City,State,Zip: ,FL, Permit Number• ��� <br /> Owner LENNAR HOMES Jurisdiction: 6116UU <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) � <br /> 1 New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ft� <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ft2 <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ftZ <br /> 4. Number af Bedrooms 5 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes <br /> 10.Ceiling Types (1946.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1772.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 3127 b.Knee Wall(Vented) R=30.0 174.00 ftz <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH: 1st Floor 6 302.4 <br /> a. U-Factor Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl, U=0.56 117.00 ftz �Z•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 86.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor� N/A ftZ a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.220 ft. <br /> Area Weighted Average SHGC: 0.303 14 Hot water systems <br /> 8. Floor Types (3181.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ftZ None <br /> c.other(see details) R= 260.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.117 <br /> Total Proposed Modified Loads: 90 98 pASS <br /> Total Baseline Loads: 92.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �.T�;S�',�T <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��'� � "= �"�p <br /> Code. calculation indicates compliance 'K+�„��''�� '-�`;c.�+. <br /> � _ i_ -','a_.�`� ,�. <br /> /' with the Florida Ener Code. � +++rrr�?�•.`:`-'°'��` <br /> PREPARED BY: - �aV� f�GG�{'JGVI 9Y "'����� �� � <br /> 5�..�..�. �. <br /> Before construction is completed � •� � ..: <br /> � .._,�t, Q <br /> DATE. this building will be inspected for � . f����i� - � . <br /> compliance with Section 553.908 : * -��: . � ,* <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ,�, <br /> with the Florida Energy Code. � �G'Ojj� �ti}� � <br /> Wfi: <br /> OWNER/AGENT: BUILDING O FIC AL: <br /> DATE. DATE: � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confrming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.050 Qn for whole house. <br /> 7/10/2017 12:03 PM EnergyGauge RO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.