Laserfiche WebLink
r � '_ <br /> FORM R405-2014 ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Re�ulation - Residential Performance Method <br /> Project Name: 3127B sf ADS Builder Name: LENNAR HOMES <br /> street: 6557 Silverado Ranch Boulevard Pe��o��� City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner CENNAR HOMES Jurisdiction: 611600 <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2907.1 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1389.30 ftz <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1309.80 ftZ <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 208.00 ft2 <br /> 4. Number of Bedrooms 5 d.N/A R= �z <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1946.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1772.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 3127 b.Knee Wall(Vented) R=30.0 174.00 ft2 <br /> z <br /> Conditioned floor area below grade(ftz) 0 °• R= ft <br /> 11.Ducts R ftZ <br /> 7. Windows(366.3 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 302.4 <br /> a. U-Factor� Dbl,U=0.54 162.68 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 323 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 117.00 ftZ 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit ' 25.2 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 86.67 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 4.220 ft. <br /> Area Weighted Average SHGC: 0.303 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (3181.0 sqft.) Insulation Area EF�0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features <br /> b.Floor Over Other Space R=0.0 1409.00 ftz None <br /> c.other(see details) R= 260.00 ftZ 15.Credits Pstat <br /> Glass/Floor Area: 0.117 <br /> Total Proposed Modified Loads: 90.98 pASS <br /> Total Baseline Loads: 92.81 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'f�sT��,.. :_ <br /> this calculation are in com liance with the Florida Ener s ecifications covered b this Q = <br /> P 9Y P Y �.�' -� �O . -., <br /> Code. calculation indicates compliance ��„��`''� `='`'.��,�+ <br /> ,{ /, with the Florida Energy Code. �n�ri''�%%:-;,�`?�ti;;;;;�'�O , <br /> PREPARED BY: �aVe �1���YG Before construction is completed �r� � � � <br /> DATE. this building will be inspected for r� ���C', � <br /> compliance with Section 553.908 *. -���. .:= * ` <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ` ':�. <br /> with the Florida Energy Code. � �G'Or.j` "��_- <br /> �;._ <br /> OWNER/AGENT. BUILDING OFFI IAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. <br /> 7/10/2017 12:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />