Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:40:45 AM
Creation date
7/31/2018 11:40:02 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18886
Building Department - Name
LENNAR HOMES LLC
Address
6557 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r � <br /> FORM R405-2014 <br /> • . _WINDOWS � <br /> Orientation shown is the entered orientation => chan ed to Worst Case. <br /> / Wall Overhang <br /> \/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 14 N=>NE 11 Metal Low-E Double Yes 0.56 0.28 23.0 ftZ 1 ft 0 in 0 ft 8 in Drapes/blinds None <br /> GARAGE <br /> # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 611 ft2 611 ftZ 72 ft 9.3 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000384 3147.9 172.81 325 .3544 7 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF.8.5 21.8 kBtu/hr 1 sys#1 <br /> 2 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 2 sys#2 <br /> COOLING SYSTEM <br /> # System Type Subtype Efficiency Capacity Air Fiow SHR Block Ducts <br /> 1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 <br /> 2 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 <br /> HOT WATER SYSTEM <br /> # System Type SubType Location EF Cap Use SetPnt Conservation <br /> 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None <br /> SOLAR HOT WATER SYSTEM <br /> FSEC Collector Storage <br /> Cert # Company Name System Model# Collector Model# Area Volume FEF <br /> None None �{2 <br /> DUCTS <br /> / —Supply— —Return— Air CFM 25 CFM25 HVAC# <br /> �� # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool <br /> 1 Attic 6 302.4 ft 1st Floor 75.8 ftZ Proposed Qn 1st Floor —cfm 75.6 cfm 0.05 0.60 1 1 <br /> 2 Attic 6 323 ft� 2nd Floor 80.75 ft Proposed Qn 2nd Floor —cfm 80.8 cfm 0.05 0.60 2 2 <br /> 7/10/2017 12:03 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.