Laserfiche WebLink
Manual S Compliance Report �ob: 3127B sfADS <br /> Date: 7/10/17 <br /> lowerfloor By: DaveAldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> � � ' • • <br /> For: Lennar Homes <br /> • . • • � <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 19757 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 2411 Btuh Entering coil WB 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 22168 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's PerFormance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 108% of load <br /> Latent capacity: 3780 Btuh 157% of load <br /> Total capacity: 25200 Btuh 114% of load SHR: 85% <br /> . • • <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 24301 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F - <br /> Manufacturer's PerFormance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity: 21800 Btuh 90% of load Capacity balance: 35 °F <br /> Supplemental heat required: 2501 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airtlow: 800 cfm <br /> Output capacity: � 7.1 kW 99°/a of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. <br /> ,� wri htsoft9 2017-Ju1-1012:13:07 <br /> 9 Right-Suite�l Universal 2017 17.0.23 RSU05714 Page 1 <br /> �'� ...S with CBA27UHE AH's\3127C sf drawn 2-2tons.rup Calc=MJS Front Door faces: N <br />