Laserfiche WebLink
,. _ -� <br /> , - <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />� Florida De artment of Business and Professional Regulation - Residential Performance Method <br /> p <br /> Project Name: 1791 Bi sf ADS Builder Name: Lennar Homes <br /> sveet: 36005 Stable Wilk Avenue Permit Office: C}t��Zephyrhills i <br /> City,State,Zip: ,FL, Permit Number � �� ? I <br /> Owner. Lennar Homes Jurisdiction:611600 I <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New constrUction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 <br /> � b.Frame-Wood,Adjacent R=11.0 331.33 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftZ <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1817.00 ft <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N!A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ftZ <br />� SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBCu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features <br /> b.N/A R= ftz None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.079 <br /> Total Proposed Modified Loads: 58.13 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �T�:S�'.q?,� .< <br /> this calculation are in compliance with the Florida Energy specifications covered by this ��� _ p <br /> Code. calculation indicates compliance � �. �,,,�''� r`"���':�� K+. <br /> with the Florida Energy Code. ���nrr��'?�:;:;.=��°;:u„�O <br /> i PREPARED BY: �l��V���j'j(,� Before construction is completed � = • '' ''� � � <br /> DATE: this buildin will be ins ected for � .-1��" - � <br /> 9 P c7 N� �p : _� . <br /> ,C - <br /> compliance with Section 553.908 �. .�'� -�- : �. <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statute's. � �. _ <br /> Y fY 9� 9 P . �? - 5. ,: <br /> with the Florida Energy Code. G'OZj'y��� .. ' <br /> OWNER/AGENT. BUILDING O FICI L: <br /> DATE: � DATE: ��� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory�ealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage � <br />' test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. ' <br /> 8/9/2017 7�16 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br /> r <br />