My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18887
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18887
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 11:42:34 AM
Creation date
7/31/2018 11:41:55 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18887
Building Department - Name
LENNAR HOMES LLC
Address
36005 STABLE WILK AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2014 • <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791 B1 sf ADS Builder Name: Lennar Homes <br /> street: 36005 Stable Wilk Avenue Perr„�t ot�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> Owner. Lennar Homes Jurisdiction:611600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= �{z <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1817.00 ft <br /> 6. Conditioned floor area above grade(ft� 1817 b.N/A R= ftZ <br /> Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor: Dbl,U=0.54 87.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 � 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1817.0 sqft.) Insulation Area EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features <br /> b.N!A R= ftZ None <br /> c.N/A R= ftZ 15.Credits Pstat <br /> Total Proposed Modified Loads: 58.13 pASS <br /> Glass/Floor Area: 0.079 <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ' .O�T�:$�'r��.� -,,_ <br /> , this calculation are in compliance with the Florida Energy specifications covered by this -�' ='�-: -O . �. <br /> �''' r`_�;`.� �'i+. <br /> Code. calculation indicates compliance � :��±.,,,rp';� ... , <br /> with the Florida Energy Code. ���.rrirr: �� `a+��;ti�O � <br /> .�'':��;:�,`;•"`� � <br /> PREPARED BY: �7G�vP���'I� Before construction is completed r�' - ; <br /> .,.. <br /> DATE: this building will be inspected for �' u`T�� ;- ' � <br /> compliance with Section 553.908 ',�., =� �� �- :: .* <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. ,+, .� <br /> Y fY 9, 9 P . �=.K- --._ . <br /> with the Florida Energy Code. COlj�y�:'t��.. - <br /> OWNER/AGENT. BUILDING OFFICIAL: <br /> DATE: DATE: � - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/9/2017 7�16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Sofiware Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.