Laserfiche WebLink
� i <br /> Pro ect Summa Job: 3127AB sf ADS <br /> � � Date: 8/1012017 <br /> lowerfloor By: DaveAldrich <br /> . . Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> � • ' • • <br /> For: Lennar Homes <br /> Notes. <br /> � - . � • <br /> Weather� Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 °/a <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 22450 Btuh Structure 17575 Btuh <br /> Ducts 1852 Btuh Ducts 2136 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification , 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 24301 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19711 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 1934 Btuh <br /> Ducts 377 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1512 1512 Equipment latent load 2311 Btuh <br /> Volume(ft3) 16162 16162 <br /> Air changes/hour 0.24 0.12 Equipment Total Load (Sen+Lat) 22023 Btuh <br /> Equiv.AVF (cfm) 64 33 Req. total capacity at 0.85 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024230-21 Cond 14HPX-024-230-21 " <br /> AHRI ref 10258598 Coil CBA27UHE-024230"++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.033 cfm/Btuh Air flow factor 0.041 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point= 35°F <br /> Backup: <br /> Input=7 kW, Output=24169 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> .c �- wrightsoftm 2017-Aug-10 13:20:33 <br /> �� Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...BA27UHE AH's\3127A8 sf ADS template 2-2tons.rup Calc=MJ8 Front Door faces: S <br />