Laserfiche WebLink
r , � <br /> . Manual S Compliance Report Job: 1941A sf AD$ <br /> Date: 8/7/2017 <br /> r En tire Ho us e By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • � <br /> For: Lennar Homes <br /> • • a s e <br /> Design Conditions <br /> Outdoor design DB� 91.3°F Sensible gain: 26103 Btuh Entering coil DB. 75.6°F <br /> Outdoor design WB. 77.3°F Latent gain: 4171 Btuh Entering coil WB• 62.8°F <br /> Indoor design DB� 75.0°F Total gain: 30273 Btuh <br /> Indoor RH. 50% Estimated airflow` 1200 cfm <br /> Manufacturer's Performance Data atActual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer� Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230'++TDR <br /> _ Actual airflow: 1200 cfm <br /> Sensible capacity: 29070 Btuh 111% of load <br /> Latent capacity� 5130 Btuh 123% of load <br /> Total capacity� 34200 Btuh 113% of load SHR: 85% <br /> • . o <br /> Design Conditions <br /> Outdoor design DB. 30.8°F Heat loss 28608 Btuh Entering coil DB. 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230"++TDR <br /> Actual airflow: 1200 cfm <br /> Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer� n/a Model: n/a+n/a <br /> Actual airflow: 1200 cfm <br /> Output capacity� 0 kW 0% of load Temp. rise: 0 °F <br /> � Meets are all requirements ofACCA Manual S. <br /> .�. wri htsoft�� 2017-Aug-0713:59:06 <br /> �� ' 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page 1 <br /> .th CBA27UHE AH's\1941A sf ADS template 3ton.rup Calc=MJB Front Door faces: N <br />