Laserfiche WebLink
y FORM R405-2014 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILD9NG CONSTRUCTION <br />� Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: R0617256 Unit 8-1 and 8-6 Builder Name: Butterfield <br /> Street: Gs108-�edrt�3t �"7 b 57 Prax�r'���� Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL,33542 Permit Number: ( �o C10 � <br /> Owner. Typical-End Units 8-1 and 8-6 Jurisdiction: 611600 <br /> Design Location: FL,Tampa County:. Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1085.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 898.67 ftz <br /> b.Frame-Wood,Adjacent R=13.0 186.67 ftz <br /> 3. Number of units,if multiple family 1 c.N/A R= ft� <br /> 4. Number of Bedrooms 3 d.N/A R= �Z <br /> 10.Ceiling Types (1435.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1435.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 1435 b.N/A R= ft' <br /> Conditioned floor area below grade(ft� 0 c.N/A R= ft2 <br /> 11.Ducts R ft' <br /> 7. Windows(137.0 sqft.) Description - Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 <br /> a.'U-Factor: Dbl,U=0.30 137.00 ft' <br /> SHGC: SHGC=0.25 , <br /> b. U-Factor. �_ N/A ft= 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 27.8 SEER:14.00 <br /> c. U-Facto�:;. N!A ftz <br /> SHGC: , 13.Heating systems kBtu/hr Efficiency <br /> d. IJ=Factor: '-' �" N/A ft' a.Electric Strip Heat 27.3 COP:1.00 <br /> . SHGC: ;.,_T; � <br /> ::;;;' Area�Weighted Ave�hge Overhang Depth: 1.672 ft. <br /> Area 1Neighted,A'vei;c�e SHGC: 0.250 1.4.Hot water systems <br /> "� a.Electric Cap:40 gallons <br /> 8. Floor Types (1435:i'sqft.) Insulation Area <br /> � EF:0.970 <br /> a.Slab-On-Grade E�ge Insulation R=0.0 1435.00 ft' b. Conservation features <br /> b.N/A � ' _ R= ftz None <br /> c.N/A ,,, „ � ;�,;,� R= �Z 15.Credits CF,Pstat <br /> �4, <br /> � " ��`` Total Proposed Modified Loads: 46.63 <br /> Glass/FloorArea: �.0095 PASS <br /> � :�� Total Baseline Loads: 46.58 <br /> t,::.�";�„ . � <br /> �'V�> . <br /> . ��F� ' <br /> r I�hereby:certify that the plans and specifications covered by Review of the plans and Q��'C�$�'x��,� <br /> this;':cai�ulation are in compliance with the Florida Energy specifications covered by this � , = - p- <br /> Code. calculation indicates compliance �ru,f''' �;:az M �`.e� <br /> .:==-�:�s� t" <br /> with the Florida Energy Code. 1� rrr�,��; ��:�.��1'�4, p <br /> PREPARED BY: • `� Before construction is completed '� � <br /> 06-�7-17 � ..._?d�_ _. � <br /> DATE: , this building will be inspected for � I-;,���.� �, <br /> compliance with Section 553.908 * :��� �. <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Code. ��+'��j,��4� <br /> OWNER/AGENT: BUILDING F IAL: <br /> DATE: DATE: <br /> - Compliance requ?�es certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-swaled in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accor�iance with R402.4.1.2. ' <br /> 6/27/2017 5:50 AM EnergyGaugeC�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br /> �� <br />