My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18979
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18979
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2018 2:21:15 PM
Creation date
7/31/2018 2:20:33 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
17-18979
Building Department - Name
LENNAR HOMES LLC
Address
6468 PADEN WHEEL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. ' <br /> Manual S Compliance Report �ab: 3711B sf ADS <br /> Date: 8/11/2017 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> ' • - • • <br /> For: Lennar Homes <br /> � • • • � <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 20060 Btuh Entering coil DB• 75.7°F <br /> Outdoor design WB: 77.3°F Latent gain: 2081 Btuh Entering coil WB. 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 22142 Btuh <br /> Indoor RH: 50% Estimated airflow� 800 cfm <br /> Manufacturer's PerFormance Data at Actual Design Conditions <br />' Equipment type: SpIitASHP <br /> Manufacturer: Lennox Model: 14HPX-024230-21+CBA27UHE-024230'`++TDR <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 21420 Btuh 107% of load <br /> Latent capacity: 3780 Btuh 182% of load <br /> Total capacity: 25200 Btuh 114% of load SHR: 85% <br /> • • � <br /> Design Conditions <br /> Outdoor design DB� 30.8°F Heat loss. 25546 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SpIitASHP <br /> Manufacturer Lennox Model: 14HPX-024230-21+CBA27UHE-024-230*++TDR <br /> Actual airflow: 800 cfm <br /> Output capacity� 21800 Btuh 85% of load Capacity balance: 36 °F <br /> Supplemental heat required: 3746 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity� 7.9 kW 105% of load Temp. rise: 50 °F <br /> Meets are all requirements of ACCA Manual S. i <br /> ,,� wri htsoft' 2017-Aug-1110:32:54 <br /> 9 Right-Suite�Universal 2017 17.0.23 RSU05714 Page� <br /> �� ..CBA27UHE AH's\37118 sf ADS template 2+ptons.rup Calc=MJ8 Front Door faces: S <br />
The URL can be used to link to this page
Your browser does not support the video tag.