Laserfiche WebLink
._ y: <br /> ; FOF2M R405-2014 <br /> �'�LORIDA ENERGY EFFICIENCY CODE FO�R BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 4259A8 sf ADS Builder Name: Lenn�r Homes <br /> street: 6489 Paden Wheel Street Permit Office: %1�R�Z�ephyrhills � <br /> City,State,Zip: ,FL, Permit Number 'Z <br /> Owner Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County�• Pasco(Florida Climate Zone 2) <br /> 1 New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ftZ <br /> b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ftz <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 <br /> 4 Number of Bedrooms 6 d.N/A R= ft' <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area <br /> a.UnderAttic(Vented) R=30.0 2347.00 ft' <br /> 6. Conditioned floor area above grade(ftz) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft= <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft' <br /> 11 Ducts R ft2 <br /> 7 Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 <br /> a. U-Factor Dbl,U=0.54 298.01 ft' b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 <br /> SHGC' SHGC=0.31 <br /> b. U-Factor Dbl,U=0.56 98.69 ft' �2•Cooling systems kBtu/hr E�ciency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Central Unit 30.0 SEER:15.00 <br /> c. U-Factor Dbl,U=0.58 72.00 ftZ <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor• other(see details) 50.00 ft' a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 <br /> Area Weighted Average Overhang Depth. 4.720 ft. <br /> Area Weighted Average SHGC- 0.305 14 Hot water systems <br /> 8. FloorTypes (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Floor Over Other Space R=0.0 2060.00 ftZ b. Conservation features <br /> b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft� None <br /> c.other(see details) R= 287.00 ft' 15.Credits Pstat <br /> Total Proposed Modified Loads. 120.59 , � A �� <br /> Glass/Floor Area: 0 122 - ��,,� <br /> Total Baseline Loads. 122.51 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ��'���7",q�.,� <br /> this calculation are in compliance with the Florida Energy " specifications covered by this � �,. '`= �, p� <br /> Code. calculation indicates compliance ��,,,,��''� =;,-'t�� � <br /> , <br /> �av� A�w��G/. with the Florida Energy Code. �+ .rrr;a�"'�%.;;;:_;�,';�*�",ti O. <br /> PREPARED BY. _ r1 �l Vl Before construction is completed w. ��t ` �""`��" � <br /> DATE: this buildin will be ins ected for � `_°'t'� ` � <br /> 9 P t7 ��l� ,:� <br /> compliance with Section 553.908 *� � '� >� <br /> I hereby certify that this building, as designed, is in compliance Florida Statutes. �,� � � �.s�,.. <br /> with the Florida Energy Code. �'O,�' ��" <br /> r'" '"'r• �"- <br /> N'�. <br /> OWNER/AGENT: �'''a"i'�'-� ��P 4 BUILDING OFFICIAL: <br /> DATE: DATE. <br /> - Compliance requires certification.by the air ha er unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. , <br /> 7/27/2017 2:42 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 <br />