Laserfiche WebLink
. � . <br /> Pro ect Summaf�, Job: 2268AB sf ADS <br /> J •' Date: 9/2512017 <br /> Entire House By: Dave <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York Ave,Hudson <br /> � • ' • � <br /> For: Lennar Homes <br /> N otes: <br /> � - • • � <br /> Weather: Tampa InternationalAP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 29983 Btuh Structure 22203 Btuh <br /> Ducts 3493 Btuh Ducts 3927 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 33476 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 26130 Btuh <br /> Method simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3009 Btuh <br /> Ducts 721 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2267 2267 Equipment latent load 3730 Btuh <br /> Volume(ft') 21250 21250 , <br /> Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 29860 Btuh <br /> Equiv.AVF (cfm) 78 39 Req. total capacity at 0.85 SHR 2.6 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-036-230-21 Cond 14HPX-036-230-21 <br /> AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR <br /> AHRI ref 10258589 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 29580 Btuh <br /> Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh <br /> Temperature rise 25 °F Total cooling 34800 Btuh <br /> Actual air flow 1200 cfm Actual air flow 1200 cfm <br /> Air flow factor 0.036 cfm/Btuh Air flow factor 0.046 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point= 33°F <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> c -�- wrightsoft' 2017-Sep-2510:02:30 <br /> �� Right-SuiteQtl Universal 2017 17.0.23 RSU05714 Page 1 <br /> ...h CBA27UHE AH's\2268AB sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W <br />