My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19065
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19065
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2018 2:15:16 PM
Creation date
8/16/2018 2:15:14 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19065
Building Department - Name
LENNAR HOMES LLC
Address
3137 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
; , <br /> , . , --� <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential PerFormance Method <br /> Project Name: 2889A1 sf ADS 2017 Builder Name: Lennar Homes 0041 <br /> street: 3137 Moulden Hollow Drive Permit o�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• <br /> Owner• Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa " County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1308.70 ftZ <br /> b.Frame-Wood,Exterior R=11.0 1114.00 ft' <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftZ <br /> 4. Number of Bedrooms 5 d.N/A R_ ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2173.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 2896 b.Knee Wall(Vented) R=30.0 140.00 ftZ <br /> Conditioned floor area below grade(ftZ) 0 °• R= ft <br /> : <br /> 11.Ducts R ftz <br /> 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358 <br /> a. U-Factor: Dbl,U=0.54 96.00 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 64.00 ftZ �2•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 <br /> b.Eentral Unit 18.0 SEER:16.00 <br /> c. U-Factor: Dbl,U=0.56 33.33 ft2 <br /> SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ftz a.Electric Heat Pump 21.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 17.5 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.172 ft. - <br /> Area Weighted Average SHGC: 0.302 14.Hot water systems <br /> 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF 0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftZ b. Conservation features <br /> b.Floor Over Other Space R=0.0 672.00 ftz None <br /> c.other(see details) R= 437.00 ftz �5.Credits Pstat <br /> Glass/Floor Area: 0.067 <br /> Total Proposed Modified Loads: 84.94 pASS <br /> Total Baseline Loads: 85.63 <br /> I hereby certify that the plans and specifications covered by Review of the plans and _ �:��iE;Sx,��,,, <br /> this calculation are in com liance with the Florida Ener � ecifications covered b this, � � ' _�:. - <br /> p 9Y P Y ���y _ � �O .��, <br /> Code. calculation indicates compliance ��'i+'�;,,��''�' `='.�,.�,�+ . <br /> /I with the Florida Energy Code. � `I�, !1{�Ir„�i!. ••;=�:�;;;-";,`�O , <br /> rj�_,,' ,_,;:`,. <br /> PREPARED BY: _ �aV� f���'l�VL Before construction is completed r� � �. <br /> DATE: this building will be inspected for � •. �� = :� - <br /> compliance with Section 553.908 *����i' � <br /> � * <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. ` ,�.- <br /> with the Florida Energy Code. ��'O.~ .��� ' <br /> D yvE:.,. <br /> OWNER/AGENT: BUILDING OFFICIAL: ' � <br /> DATE. DATE: - '� <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. � <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 10/13/2017 7:06 AM EnergyGaugeOO USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.