Laserfiche WebLink
Y_ j <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1791A sf ADS Builder Name: Lennar Homes <br /> street: 3192 Moulden Hollow Drive Permit o�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number• l�b�/', <br /> Owner. Lennar Homes Jurisdiction: 611600 <br /> Y' <br /> Design Location: FL,Tampa County Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 331.33 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R_ ftZ <br /> 4. Number of Bedrooms 4 d.N/A R_ ft2 <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area <br /> a.UnderAttic(Vented) R=30.0 1817.00 ft� <br /> 6. Conditioned floor area above grade(ftz) 1817 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft2) 0 °• R= ft <br /> z <br /> 11.Ducts R �2 <br /> 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 <br /> a. U-Factor• Dbl,U=0.54 87.00 ftz <br /> - SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 - <br /> c. U-Factor: Dbl,U=0.56 23.00 ftZ <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.233 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. Floor Types (1817.0 sqft.) Insulation Area EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features <br /> b.N/A R= ft� None <br /> c.N/A R= ft2 <br /> 15.Credits Pstat <br /> Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.08 pASS <br /> Total Baseline Loads: 58.11 <br /> I hereby certify that the plans and specifications covered by Review of the plans and ���kI�;ST�j�, ,. <br /> this calculation are in compliance with the Florida Energy specifications covered by this � �!_. ' ":�,`�p� ., <br /> Code. calculation indicates compliance �k�y,,-''� `='�-�'�;.�,-,�c+ . <br /> ��::a��. {. <br /> �" with the Florida Energy Code. F+ �nr+�%%-;;:��?;.a�-„ .O ` <br /> PREPARED BY: �G�V2 �GD�j'(GYC Before construction is completed 'r� ' -'" `"�C,". <br /> DATE: this building will be inspected for � �-j'�;1�!- -" .� � <br /> compliance with Section 553.908 ' *. = :11� � .� - <br /> I hereby certify that this building,as designed, is'n compliance Florida Statutes. . ' ,t. ' <br /> with the Florida Energy Code. �G'p � <br /> D yy�;� ._ <br /> OWNER/AGENT: BUILDING O FICIAL. <br /> DATE. � DATE: - <br /> - Compliance requires certification y the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 7/14/2017 9:12 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 <br />