My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19067
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19067
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2018 2:18:05 PM
Creation date
8/16/2018 2:18:03 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19067
Building Department - Name
LENNAR HOMES LLC
Address
3172 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� J <br /> i <br /> FORM R405-2014 ' <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTjRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Perform�nce Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> street: 3172 Moulden Hollow Drive Perr„�t o��: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number:rG��(o', <br /> Owner. Lennar Homes ,lurisdiction: 6116600 <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ft� <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4 Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? 10.Ceiling Types (1936.0 sqft.) Insulation Area <br /> Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 <br /> 6. Conditioned floor area above grade(ft� 1936 b.N/A R= ftZ <br /> Conditioned floor area below grade(ft') 0 c.N/A R= ftZ <br /> 11.Ducts R ftZ <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ft� <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft� 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor: Dbl,U=0.56 23.00 ftz <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (1936.0 sqft.) Insulation Area <br /> EF:0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ftz 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.81 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and �Z�,ST,q7,._ ._ <br /> this calculation are in compliance with the Florida Energy specifications covered by this ,�S'� _ _,�0�,: �. <br /> Code. calculation indicates compliance '�'K?"�,,,''' r`',_;..��:�� .�:c+ . <br /> �:�" a��` 'r ' <br /> �ave �C�fi�cl� With the Florida Energy Code. I+ ri„r���;,;:;z''�.-;;�U,ti O <br /> .. ..,.:.�_. .� <br /> PREPARED BY: Before construction is completed ' � ' - � � <br /> a � �.�;_ _. _. o <br />� DATE. this building will be inspected for ;� .�I�kj�, �. <br /> � compliance with Section 553.908 *, �'��_ ; * <br /> I hereb certi that this buildin as desi ned, is in com liance Florida Statutes. - <br /> Y fY 9, 9 P -'�G, :< �c�'t , <br /> with the Florida Energy Code. � O,rj�yy�:� . <br /> OWNER/AGENT: -�- BUILDIN FFICIAL: <br /> DATE. ° DATE: ' - <br /> - Compliance requires certificatio by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. <br /> 8/7/2017 2:03 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.