Laserfiche WebLink
� � <br /> FORM R405-2014 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1941A sf ADS Builder Name: Lennar Homes <br /> street: 3172 Moulden Hollow Drive Permit o�ce: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number <br /> � Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County� Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftZ <br /> b.Frame-Wood,Adjacent R=11.0 506.78 ftZ <br /> 3. Number of units,if multiple family 1 c.N/A R= ftz <br /> 4. Number of Bedrooms 4 d.N/A R= ftZ <br /> 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area Z <br /> a.Under Attic(Vented) R=30.0 1936.00 ft <br /> 6. Conditioned floor area above grade(ft� 1936 b.N/A R= ftz <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ftz <br /> 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 <br /> a. U-Factor: Dbl,U=0.54 101.00 ftZ <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.56 33.33 ft2 72-Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 <br /> c. U-Factor Dbl,U=0.56 23.00 ft2 <br /> SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.212 ft. - <br /> Area Weighted Average SHGC: 0.308 14.Hot water systems <br /> 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> EF.0.950 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= �Z 15.Credits Pstat <br /> Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.81 pASS <br /> Total Baseline Loads: 62.65 <br /> I hereby certify that the plans and specifications covered by Review of the plans and 'C��.. �'�q .. .; <br /> S . <br /> ,:Q�: .- " _ .`.fi�_ <br />, this calculation are in compliance with the Florida Energy specifications covered by this � ��' ,!; ��.�;; O�,_ <br /> Code. calculation indicates compliance 4.'��;,-''' _=�';.��, .Ys+ <br /> `J _ , ,*a�P C`. ' <br /> �aVe ���G� with the Florida Energy Code. �F+ rr�ri.�'%:-;;_�:.�;:;�'^ti� � , <br /> •. - .�, <br /> PREPARED BY: Before construction is completed 'r� � �� ' •• <br /> DATE. this building will be inspected for � . `��i- ; �. <br /> compliance with Section 553.908 *. -�' � - , ; =*, ` <br /> I hereb certi that this buildin as desi ned,is in com liance Florida Statutes. , <br /> with the Florida Ener Code. 9 9 p �C�':�" `t����- <br /> 9Y D y�.:,� <br /> OWNER/AGENT: BUILDING FFICIAL: <br /> DATE: DATE: ' - <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> �certified factory-sealed in accordance with R403.2.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br />' - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, <br /> tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. <br /> 8/7/2017 2:03 PM EnergyGaugeOO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 <br />