My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19068
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19068
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/16/2018 2:19:18 PM
Creation date
8/16/2018 2:19:16 PM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
17-19068
Building Department - Name
LENNAR HOMES LLC
Address
3186 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I � <br /> ` . , . <br /> FORM R405-2014 . <br /> WALLS <br /> Adjacent Spa� Cavity Width Height Sheathing Framing Solar Below <br /> 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 S 160.0 ftZ 0 0.600000 0 <br /> 2 E=>SE Exterior Concrete Block-Int Insui Main 4.0999 54 8 432.0 ftZ 0 0.600000 0 <br /> 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ftZ 0 0.600000 0 <br /> 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 <br /> _ 5 N=>NE Garage Frame-Wood Main 11 19 8 152.0 ft2 0 0.01 0 <br /> _6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ftZ 0 0.01 0 <br /> 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 � 8 48.0 ftZ 0 0.600000 0 <br /> DOORS <br /> # Omt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 <br /> 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ftZ <br /> WINDOWS <br /> Orientation shown is the entered orientation => chan ed to Worst Case. <br /> / Wall Overhang <br /> V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 16.0 ftZ 1 ft 0 in 4 ft 0 in Drapes/blinds None <br /> 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 16.0 ft' 1 ft 0 in 1 ft 0 in Drapes/blinds None I <br /> 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 16.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ftZ 2 ft 0 in 0 ft 6 in Drapes/blinds None <br /> 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 23.0 ftZ 1 ft 0 in 1 ft 0 in Drapes/blinds None <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 408 ft2 408 ftz 40 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000254 ' 1036.7 56.91 107.03 .1906 5 <br /> HEATING SYSTEM <br /> # System Type Subtype Efficiency Capacity Block Ducts <br /> 1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 <br /> 9/13/2017 12:05 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.