Laserfiche WebLink
,, ; . ' ' . . <br /> Pro ect Summar�� Job: 1551B sf ADS <br /> 1 '1 Date: 911312017 <br /> Entire House By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> ' � - • � <br /> For� Lennar Homes <br /> N otes: <br /> � - � • • <br /> , Weather: Tampa International AP, FL, US \ <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 39 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 19769 Btuh Structure 17023 Btuh <br /> Ducts 1901 Btuh Ducts 2200 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 21670 Btuh Use rrianufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 19223 Btuh <br /> Method simplitied Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2479 Btuh <br /> Ducts 391 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1555 1555 Equipment latent load 2870 Btuh <br /> Volume(ft') 12438 12438 , <br /> Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 22092 Btuh <br /> Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton <br /> '� <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Lennox Make Lennox <br /> Trade 14HPX SERIES Trade 14HPX SERIES <br /> Model 14HPX-024230-21 Cond 14HPX-024-230-21 <br /> AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR <br /> AHRI ref 10258598 <br /> Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER <br /> Heating input Sensible cooling 21420 Btuh <br /> Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh <br /> Temperature rise 25 °F Total cooling 25200 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0 in H20 Static pressure 0 in H20 <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Capacity balance point= 32°F <br /> Backup: n/a n/a <br /> Input= 0 kW, Output= 0 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> C. "� wrightsoft� 2017-Sep-1312:11:07 <br /> �� Right-Suite�Universal 2017 17.0.23 RSU05714 page 1 <br /> .with CBA27UHE AH's\1551B1 sf ADS drawn 2ton.rup Calc=MJ8 Front Door faces:NW <br />