My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18480
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18480
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 1:46:27 PM
Creation date
9/17/2018 1:45:42 PM
Metadata
Fields
Template:
Building Department
Company Name
SUNRISE PROPRERTIES OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
17-18480
Building Department - Name
SUNRISE PROPERTIES OF ZEPHYRHILLS
Address
4035 CORREIA DR
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
= Project: C0117003 { <br /> Title: Sunrise Manufacturing <br /> Type: Manufacturing Facility � <br /> (WEA File: FL_TAMPA INTERNATIONAL AP.tm3) � <br /> System Report Compliance � <br /> AHiTl-5 AHU1=5 Constant Volume Air Cooled No.of Units <br /> Split System<65000 Btu/hr 5 <br /> Component Category Capacity Design Eff Design IPLV Comp- ; <br /> Eff Criteria lPLV Criteria liance ' <br /> Cooling System Air Condirioners Air Cooled 57000 14.00 13.00 8.00 PASSES � <br /> Split System<65000 Btu/h <br /> Cooling Capacity <br /> Heating System Heat Pumps Air Cooled 54500 8.20 7.70 PASSES � <br /> ; <br /> (Heating Mode)Split System <br /> <65000 Btu/h Cooling <br /> Capacity <br /> Air Handling Air Handler(Supply)- 1900 0.00 0.82 PASSES i <br /> System-Supply Constant Volume , <br /> Air Handling Air Handler(Return)- 1900 0.00 0.82 PASSES � <br /> System-Return Constant Volume ' <br /> i <br /> AHU6-7 AHU6-7 Constant Volume Air Cooled No.of Units � i <br /> , <br /> Split System<65000 Btu/hr 2 ! <br /> Component Category Capacity Design Eff Design IPLV Comp- � <br /> Eff Criteria lPLV Criteria liance � <br /> Cooling System Air Conditioners Air Cooled 46000 14.00 13.00 8.00 PASSES I <br /> Split System<65000 Btu/h <br /> Cooling Capacity <br /> � <br /> Heating System Heat Pumps Air Cooled 45500 8.20 7.70 PASSES ' <br /> (Heating 1Vlode)Split System <br /> <65000 Btu/h Cooling <br /> Capacity � � <br /> Air Handling Air Handler(Supply)- 1533 0.00 0.82 PASSES <br /> System-Supply Constant Volume ' <br /> Air Handling Air Handler(Return)- 1533 0.00 0.82 PASSES � <br /> System-Return Constant Volume ; <br /> -- - I <br /> PASSES <br /> , � <br /> EnergyGauge Summit0 Fla/Com-2014.TAM 2014-1.0 Compliant Soflware.Effective Date:June 30,2015 <br /> Florida Building Code,Fifth Edition(2014)-Energy Conservation IECC 2012-Total Building Performance Compliance Option ; <br /> 1/11/2017 Page 6 of 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.