My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-18480
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-18480
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 1:46:27 PM
Creation date
9/17/2018 1:45:42 PM
Metadata
Fields
Template:
Building Department
Company Name
SUNRISE PROPRERTIES OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
17-18480
Building Department - Name
SUNRISE PROPERTIES OF ZEPHYRHILLS
Address
4035 CORREIA DR
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> � <br /> ' ' Job: C0117003 I <br /> RightSuiteO Universal 2017 Load Summary � <br /> • �" wrightsoft° Date: 01-03-17 � <br /> COpj/RIi1 By: JND � <br /> Randy Watson Designs, Inc <br /> 13821 US Highway 98 By Pass,Dade City,FL 33525 Phone:352-523-2077 i <br /> � • ' . • ' \ <br /> I <br /> For: Sunrise Manufacturing . <br /> Zephyrhills, FL • <br /> Zone: Copy Rm COO�ING LOAD� <br /> 1. DESIGN CONDITIONS at Jul 1800 LDT Peak load at Jul 1700 LDT <br /> ' Inside: 75 °F Outside: 90 °F TD: 15 °F <br /> RH: 56 % MoistDiff: 53.9 gr/Ib Mult: 1.0 Ins.wb 63 °F <br /> � Sensible Latent <br /> 2. SOLAR RADIATION THROUGH GLASS � 0 ' - , <br /> 3. TRANSMISSION GAINS Sensible 359 - <br /> Walls: 359 - - � <br /> Glass: 0 - - , <br /> Doors: 0 - - <br /> , Partitions: 0 - - � <br /> Floors: 0 ' - - <br /> Ceilings: 0 - - � <br /> 4. INTERNAL HEAT GAIN Sensible Latent 1267 0 ' <br /> Occupants: 0 0 - - ; <br /> Lights: 188 - - - <br /> Motors: 0 - - - � ; <br /> Appliances: 1079 0 - - , � <br /> 5. INFILTRATION: Outside air cfm: 0 0 0 � <br /> 6. SUBTOTAL: Space load Sensible � Latent 1626 0 . � <br /> Envelope 1626 0 - - <br /> Less external 0 - - - i <br /> Redistribution 0 0 - - � <br /> 7. SUPPLYDUCT 0 - ' <br /> 8. SUBTOTAL: Space load+ supply duct 1626 - <br /> Actual cfm: 92 at supply TD: 20 - - ' <br /> 9. VENTILATION: Make-up air cfm: 11 179 397 <br /> 10. RETURPIAIR LOAD: Lighting+ plenum (net) 0 - <br /> 11. RETURN DUCT 0 - <br /> 12. TOTAL LOADS ON EQUIPMENT 1804 397 � <br /> � HEATING LOAD <br /> 13. DESIGN CONDITIONS MUIt: 1.0 <br /> Inside: 70 °F Outside: 43 °F TD: 27 °F � <br /> 14. TRANSMISSION LOSSES 648 � <br /> Walls: 398 - <br /> Glass: 0 - ; <br /> Doors: 0 - <br /> Partitions: 0 - ; <br /> Floors: 250 - <br /> Ceilings: 0 - � <br /> 15. INFILTRATION: , Outside air cfm: 24 703 I <br /> 16. SUBTOTAL: Space load 1351 <br /> Envelape 1351 - � <br /> Less external 0 - , <br /> Less transfer 0 - � <br /> Redistribution 0 - � <br /> ' 17. SUPPLY DUCT: 0 I <br /> 18. VENTILATION: Make-up air cfm. 11 323 � <br /> 19. HUMIDIFICATION 416 <br /> Piping 0 <br /> 20. RETURN DUCT 0 <br /> 21. TOTAL HEATING LOAD ON EQUIPMENT 2090 <br /> � WI'1 �'It50ft' 2017-Jan-1115:47:56 <br /> 9 Right-Sufte�Universal 2017 17.0.10 RSU07440 Page 8 <br /> \C0117003-Sunrise Manufacturing1C0117003b.rup Calc=MN5 House Front faces:SE ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.