Laserfiche WebLink
'� FORM R405-2014 <br /> {NALL.S <br /> Adjacent spa�� Cavity Width Height Sheathing Framing Solar Befo w <br /> 1 N Exterior Concrete Block-F�ct In3r6�ster Bedro 5 14 8 8 0 117.3 ft2 0 0 0.3 0 <br /> 2 E E7cterior Goncrete Block-Ext In��ster Bedra 5 ' 8 0 8 4 B4.0 ft2 0 4 0.3 0 <br /> 3 W Exterior Concrete Block-F�ct In�ddster Bedro 5 8 Q 8 0 64.0 ft2 4 0 0.3 0 <br /> 4 W E�erior Co�crete Block-E�Ins�edroom3 5 '14 0 8 Q 112.0 ftx 4 0 0.3 0 <br /> 5 S Exterior Concrete Block-Ext Ins�edroom2 5 12 0 8 p 96.0 ftz 0 0 0.3 0 <br /> 6 W Exferior Cancrete Biock-E�ct 1ns�edraom2 5 41 8 8 0 93.3 R2 d 0 0.3 0 <br /> , 7 S Exterior Concrete Block-F�ct Insul Entry 5 5 0 8 0 40.0 ft2 0 0 0.3 0 <br /> 8 N Exteriar Goncrete B1ock-�ct In�teat Rm"Din 5 14 0 8 0 112.0 ft2 0 0 d.3 0 <br /> 9 W Exterior Concrete Block-Exct In�teat Rm Din 5 25 0 8 Q 200.0 ft2 0 0 0.3 0 <br /> _9 Q S �arage Frame-Woad Entry 13 9 4 8 8 4 93.3 ff2 0 0 0.41 0 <br /> _11 S Garage Frame-Wood Bath2 13 6 4 8 0 50.7 ft2 0 0 0.01 0 <br /> _12 S Garage Frame-Wood �.aundry 13 5 4 8 0 42.7 ft2 0 0 d.di 0 <br /> DQQRS <br /> # Omt Door Type Space Storms U-Value Width Height Area <br /> Ft tn Ft !n <br /> 1 S Insulated Entry None .35 3 6 $ 20 ftZ <br /> 2 N Insulated Great Rm Din None .35 3 B 8 2Q ft2 <br /> ' 3 S insulated Entry None .35 2 8 6 8 17.8 ft= <br /> WIND0INS <br /> 4rientation shown is the entered,Pro osed orientation. <br /> j 11�?ail Overhang <br /> V # Ornt (D Frame Panes NFRC U-Factar SHGC Area Depth Separation Int Shade Screening <br /> 1 N 1 TIM Low-E Double Yes Q.3 0.25 30.0 ftZ 1 ft Q in 't ft 2 in Drapesibtinds Exierior 5 <br /> 2 W 4 TIM Low-E Double Yes 0.3 0.25 15.0 ft' 1 ft 0 in 1 ft 2 in Drapes/blinds Eacterior 5 <br /> 3 S 5 TiM Low-E Double Yes 4.3 Q.25 ZQ.O ft= 1 ft 0 in 1 ft 2 in Drapesibiinds Exterior 5 <br /> 4 W 6 TIM Low-E pouble Yes 0.3 0.25 15.0 ftz 1 ft 0 in 1 ft 2 in Drapes/blinds E�cterior 5 <br /> 5 N 8 TIM Low-E Doubie Yes 4.3 0.25 12.0 82 8 ft 8 in 1 ff 2 in Drapesiblinds EScterior 5 <br /> 6 W 9 TIM Low-E Double Yes 0.3 0.25 15.0 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds E�erior 5 <br /> ? W 3 TtM Low-E Double Yes 0.3 0.25 30.Q ftZ 1 ft 0 in 1 it 2 in DrapeslbJinds F�cteriar 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wali Insulation <br /> 1 234 ft2 234 ft2 64 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 5Q ELA EqLA ACN ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .p00356 1339.3 73.53 138.28 .2669 7 <br /> � <br /> 6/27l2017 5:54 RM EnergyGaugefl tJSA-F1aF2es2014 Section R405.4 1 Compliant Saftware Page 4 of 5 <br />