Laserfiche WebLink
i, + • L <br /> FORM R405-2014 <br /> WALLS <br /> Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w <br />' 1 N Exterior Concrete Block-Ext In3Y7dster Bedro 5 14 8 '8 0 117.3 ftz 0 0 0.3 0 <br /> 2 E Exterior Concrete Block-Ext In�'I�ster Bedro 5 S 0 8 0 64.0 ftZ 0 0 0.3 0 <br /> _3 W Exterior Concrete Block-Ext In3r7dster Bedro 5 8 0 S 0 64.0 ft' 0 0 0.3 0 <br /> 4 W Exterior Concrete Block-Ext Ins�edroom3 5 14 0 8 0 112.0 ft� 0 0 0.3 0 <br /> 5 S Exterior Concrete Block-Ext Ins�edroom2 5 12 0 S 0 96.0 ft� 0 0 0.3 0 <br />, 6 W Exterior Concrete Block-Ext Ins�edraom2 5 11 8 8 0 93.3 ft� 0 0 0.3 0 <br /> _ 7 S Exterior Concrete Block-Ext Insul Entry 5 5 0 8 0 40.0 ft� 0 0 0.3 0 <br /> 8 N Exterior Concrete Block-Ext In�'mteat Rm Din 5 14 0 8 0 112.0 ft2 0 0 0.3 0 <br /> 9 W Exterior Concrete Block-Ext In�deat Rm Din 5 25 0 8 0 200.0 ftZ 0 0 0.3 0 <br /> _10 S Garage Frame-Wood Entry 13 11 8 8 0 93.3 ft' 0 0 0.01 0 <br /> i _11 S Garage Frame-Wood Bath2 13 6 4 8 0 50.7 ft2 0 0 0.01 0 <br /> _12 S Garage Frame-Wood Laundry 13 5 4 8 0 42.7 ftZ 0 0 0.01 0 <br /> DOORS <br /> # Ornt Door Type Space Storms U-Value Width Height Area <br /> Ft In Ft In <br /> 1 S Insulated Entry None .35 3 6 8 20 ftZ <br /> 2 N Insulated Great Rm Din None .35 3 6 8 20 ftZ <br /> i <br /> 3 S Insulated Entry None .35 2 8 6 8 17.8 ft' <br /> wirv�ows <br /> Orientation shown is the entered,Pro osed orientation. <br /> / U•!all Overhang <br /> \� # Omt ,D Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening <br /> 1 N 1 TIM Low-E Double Yes 0.3 0.25 30.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 2 W 4 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 3 S 5 TIM Low-E Double Yes 0.3 0.25 20.0 ft� 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 4 W 6 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 5 N 9 TIM Low-E Double Yes 0.3 0.25 12.0 ftZ 8 ft S in 1 ft 2 in Drapes/blinds Exterior 5 <br /> 6 W 9 TIM Low-E Double Yes 0.3 0.25 15.0 ftZ 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 <br /> 7 W 3 TIM Low-E Double Yes 0.3 0.25 30.0 ftZ 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 <br /> GARAGE <br /> # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation <br /> 1 234 ftZ 234 ft2 64 ft 8 ft 1 <br /> INFILTRATION <br /> # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 <br /> 1 Wholehouse Proposed ACH(50) .000356 1339.3 73.53 138.28 .2669 7 <br /> 6/27/2017 5:50 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 � <br /> . � <br />