Laserfiche WebLink
� . <br /> FORM R4d5-2014 - <br /> ItIfAN��►1`ORY REd�UiRE!!ltENTS - (Cantinued} <br /> � R403.2.3 Building Cavities(Mandatory). Building framing cavities shafi not be used as ducts or plenums. <br /> C! E2403.3 Mechanica!system piping insuEation{Mandatoryj. Mechanical system piping capable of carrying fluids above 105°F(41°C) ' <br /> or below 55°F(13°C}shail be insulated to a minimum of R-3., <br /> R403.3.1 Protectlon of piping insutation. <br /> � R403.4.1 Circuiating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic ar readily <br /> accessible manual switch that can turn off#he hot-water circulating pump when the system is not in use. <br /> � R403.4.3 Hea#fraps{ittlandatory}. Storage water heaters not equipped with infegra(heat#raps and having vert9eal pipe risers shall ave <br /> heat traps installed on both lhe inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a <br /> downward and upward bend of at least 3'/inches(89 mm)in the hot water distribution line and cold water line located as close as possible <br /> ta the starage fank. � <br /> � Rd03.4.4 Water heater efficiencies(Mandatory). <br /> � R4Q3.4.4.3 Storage water heater temperature contro]s <br /> . R403.4.4.1.1 Automatic cantrols. Service water heating systems shall be equipped with automatic kemperature controls <br /> capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum <br /> femperafure setting range shall be fram 100°F to'I40°F{38°C ta 60°C}. <br /> . R403.4.4.1.2 Shut down. A separate switch or a clearly marked clrcuit breaker shall be provided to permit the power supplied <br /> ta electric service systems fo be turned aff.A separate valve shali be provided ta permit tt�se snergy suppIied to the main burner(s} <br /> of combustion types of service water heating systems to be turned off. <br /> p R443.4.4.2 Water heating equipment Water heating equipment instailed in residen6a!uniFs shaii meet the minimum efticiencies of <br /> Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Cammerciai Provisions,for the type of equipment installed. <br /> Equipment used ko provide heating functions as part of a combinatian system shall satisfy all stated requirements for the appropriate water <br /> heat9rrg cafegory. Solar water heaters shail met the criteria Sectian R403.4.4.2.9. <br /> . R403.4.4,2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy <br /> facfor of the system.The solar energy factor of a system shail be determined from the Florida Solar Energy Centet Directory of <br /> Certifed SoEar Systems.Sotar eollectors shali be fested in accordance with ISt3 Sfandard 9806,Test tJleihads for Solar Callectors, <br /> and SRCG Standard TM-1,Solar pomestic Hot Water System and Componenk Test Protocol,Collectors in installed solar water. <br /> hea6ng systems shauld meet the following criteria: � <br /> 1. Be installed with a tilt angte between 10 degrees and 40 degrees of#he horizontai;and <br /> 2. Be installed at an orientation within 45 degrees of true soulh. <br /> (� R4d3.5 Mechanieal ventitation(Niandatory}. The building sha11 be pro�ided wifh ventilafion that meets fhe requirements of the <br /> Florida Building Code,Residential ar Florida Building Code,Mechanical,as applicable,or with other approved means of ventila#ion. <br /> Outdoar air intakes and exhausts sha!!have automatic or gravity dampers that close when the ventilatian system is not operating. <br /> p R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. <br /> � R443.6.4 Equipment sizing. Fieating and cooling equipment shali be sized in accordance with ACCA Nlanual S based on the <br /> equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling caiculation methodologies, <br /> based an building loads for the dlrectional orientatian of the building.The manufacturer and model number of the outdoor and <br /> indoor units(if split system}sha3l be submitted alang wifh the senstbte and totai coaling capacities at the design conditians <br /> described in Section R$02.1.This code does not allow designer safety factors,provisions for future expansian or other factors <br /> which atfect equipment sizing.System sizing calculations shali not include laads created by local intermittent mechanical ventilation <br /> suctt as siandard kitchen and bathroam exhausf sysfems. <br /> • R403.6.1.1 Cooling equipment capacity. Cooling aniy equipment shail be selected so that its total capacity is not less than the <br /> calculated tofat load,buf not more fhan 9.15 times greater than the fotai load caicutated according to the procedure selected in <br /> Section 4Q3.6,or the ctosest avaiiabte size provided by fhe manufacturer's product(inas.The correspanding iafent capacify of the <br /> equipment shall not be less than the calculated latent load. <br /> 9/7/2017 7:51 AM EnergyGauge�USA-FlaRes2014 -8ection R405.4.1 Com Page 2 of 3 <br />