My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19005
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 1:58:54 PM
Creation date
9/17/2018 1:58:46 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19005
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6780 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-20'i4 <br /> MAND�4TORY 4�E�UIREfNiERlT� - (Continued) <br /> � R403.6.1.1 Coaling equipmen#capacify.(continued} The pub(ished va(ue far AHR!tafal capacity is a nominal,rating-test value and <br /> shall nat be used for equipment sizing.Manufacture's expanded performance data shall be used ta select cooling-anly equipment.This <br /> se{ecfion shall be used fo select cooling-only equipment.This selection shaii 6e hased oa the outdoor design dry bulb temperature for the <br /> Ioad cafculation(or entering water temperature for water-source equipmeni},the btawer cfm provided by the expanded pe�ormance dafa, <br /> the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. <br /> Design values far entering wet bulb and dry bulb temperature shall be(o�the indoor dry bul6 and relative humidity used for the load <br /> calculalion and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. <br /> Excep#ions: <br /> 1 Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the <br /> calculated total sensible loed but not less than 80 percent of that load. <br /> 2. When signed and sealed by a Florida-registered engineer,fn attached single-and multi-famiiy units,the capacity of <br /> equipm�nl_m�be sized in accordance with good design practice. <br /> � R403,6.1.2 Heating equipment capacity <br /> ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section <br /> RA63.&.'1.1 and the heat pump tota(cooling capaeity shatl not be more than 1.15 times greater than the design cooling Ioad. <br /> . R403.6.9.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design <br /> requiremenfs calculafed according to the procedure selected'm Section ft443.B.1. <br /> ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners <br /> sha(i nof be less than fhe design laad calculated in accordance wiEh SecUon R403.6.1. <br /> � R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an <br /> infermiftenf basis,such as anBcipafed additianal loads caused by major eniertainment events,shall have equipmsnt sized or controtled ta <br /> prevent continuous space cooling or fieating within that space by one ar more of the fo!(owing optians: <br /> 1. A separate cooling or heating system is utilized to provide coaling or heating to the major entertainment areas. <br /> 2. A variabie capacify system sized for optimum performance during base toad periods is utiiized. <br /> p t2443.7 Systems serving multiple dwelling units(Mandatorya. Systems serving multiple dwelling units shall comply wilh Sections <br /> C403 and C404 oE the Commercial Provislons'sn lieu nf Section R4d3. <br /> ❑ R403.8 Snow melt system controls(Mandatory), Snow and ice-melting systems,supplied through energy service to the building,shall <br /> include aufomatic controls capa6le af shutting off fhe sysfem when fhe pavement tempetature is abova 55°F,and no precipitation is falling <br /> , and an automatic or manual control that will ailow shutoff when the outdoor temperature is above 40°F. <br /> Cl R4Q3.9 Swimming paals,inground spas and portable spas{Mandataryj. The energy requirements for ressdentia!paofs and <br /> inground spas shalt be as specified in Sections R403.9.1 througfi R403.9.3 and in accorda�ce with ANSIIAPSP-i 5.The energy <br /> requirements for portable spas shall be in accordance with ANSI/APSP-14. <br /> p R4a3.9.1 Pool and spa heafers. AlI pool heaters shaf{be equipped with a readily accessibie on-aff switch that is mounfed <br /> outside the heater to allow shutting off the heater without adjusting the thermostat setting. <br /> i2403.9.4.1 Gas and oil-fired paot and spa heaters. Ati gas-and aii-fred poal and space heaters shall have a minimum <br /> thermal efficiency of 82 percent far heaters manufactured on or after April 16,2013 when tested in accordance wifh ANSi Z 21.56. <br /> Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. <br /> , R4d3.9.�1.2 Heat pump pool heafers. Heat pump poat heafers shall have a minimum COP of 4.0 when tested in accordance <br /> with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independeni laboratory is <br /> � required to verify procedure compliance.Geothermaf swimming pool heat pumps are not required to meet this standard. <br /> O R403.9.2 Time switches. Time switches or other control method that can automaticaily turn off and on heaters and pumps according to a <br /> preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in <br /> campiiance with this equlpment. <br /> Exceptions: <br /> • 1 Where pubiic health standards require 24-hour pump operations. <br /> 2. Where pumps are required to operate solar-and waste-heat-recavery pool heafing sys#ems. <br /> 3. Where pumps are powered exclusively from on-site renewable generation. <br /> O R443.9.3 Covers. Heated swimming paols and inground permanentiy instalied spas shali be equipped wifh a vapoe retardant caver on ar <br /> at the water surface or a liquid cover or other means proven to reduce heat loss. <br /> Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or <br /> ' soiar ene�gy source computed over an operating season. <br /> ❑ RR404.1 Lighting equipmenE(Mandatory). A minimum of 75 percent af the lamps in permanently installed lighting fixtures shall be <br /> high-efficacy lamps or a mfnimum of 75 percent of permanenfiy instailed isghiing fixtures sha0 contain anly high e�cacy Iamps. <br /> Exception: Low-vottage fighting shalf not be required to utilize high-efficacy lamps. <br /> � R404.9.9�tghting equipmeat(Mandatory). Fuel gas Ilghting systems shall not have continuously burning pilot lights <br /> � R405.2 PerFormance dNLY. A(i ducts not entirely inside the building thermat envefape shall be insulated to a minimum of R-6. <br /> O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of F2-19.Where single assemby of the exposed deck and beam type or <br /> concrete deck roofs do nat have su�cent space,R-14 is aliawed. <br /> 9/7l2017 7:51 AM EnergyGauge�USA-FlaRes2014 -Section R405.4,1 Com P�ge 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.