Laserfiche WebLink
, _ , � _. <br /> i , 1; <br /> r ' <br /> FORM R405-2094 <br /> Florida Department of Business and Professional Regulations <br /> Residentia! Whole Buildin Performance and Prescri tive Methods <br /> AdDftES9: Permit Number <br /> Dade City,FL, <br /> i�iA(�DAT4RY REQUIREi11fENT$See individual code sections for full details. <br /> � 401.3 Energy Perfarmance Levei(ERL}display card(Mandatary}. The 6uilding o�cial shaIl require that an energy perfarmance level(EPI.} <br /> display card be comp(eted and certified by fhe buiider to be accurate and cocrect before fina!approval of the building for occupancy.Florida law <br /> (Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and <br /> nonpresold residential buildings.The EPL disptay card confains information indicating the snergy performance level and e{ficiencies of components <br /> installed in a dwelling unit.The buifding o�cia!shail verity that the EPL.display card completed and signed by the builder accurately reflects the plans <br /> and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. <br /> � R402.A Air leakage(Mendatory). The building thermal envelope shall be canstructed to Iimit air leakage in accordance with the requirements af <br /> Sections R462.1 through R4d2.A.4. <br /> p Ft402.4.1 Buitding thermal envelopa. The buiiding therma(enveiape shall comply with Sect�a"�ns R402:4-9:1 and-E2402.-4:'t:2.—The <br /> sea(ing methods between dissimilar materials shall allow for differential expansion and contraction. <br /> � R402.4.1.1 instailatian.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be insfalled in <br /> accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1 1,as applicable to ihe method of construction. <br /> Where required by khe code officiai,an approved third party shali inspect aq camponents and veriiy compliance. <br /> • R402.4.1.2 7esting. The building or dwelling unit shali be tested and verified as having an air Ieakage rate of not exceeding 5 air <br /> changas per hour in Ciimate Zanes 1 and 2,and 3 aIr changes per hour in Glimate Zanes 3 fhrough 8.Testing shal!be conducted w�th <br /> a hlower door at a pressure of 0.2 inches w.g.{50 Pascals).Where required by the code official,testing shall be conducted by an <br /> approved third party.A written report of the results of the test sha(f be signed by fhe party conducGng tfle test and provided to the code <br /> o�ciel.Testing shall be performed at any fime afEer creation af all penetrations af the bu9lding therma!envelope. <br /> During festing: <br /> 1.Exterior windaws and daors,fireplace and stove daors sha!!be closed,but not sealed,beyond the intended weatherstripping or <br /> other infiltration control measures; <br /> 2.Qampers including exhaust,intake,makeup air,backdraft and flua dampers shall be c(osed,but nat seaSed beyond inte�ded <br /> infiliratian contro!measares; <br /> 3.Interior doors,if installed at the time of the test,shall be open; <br /> 4.Exterior doors for continuous venti(ation systems and heat recovery ventilators sha(I be closed and sealeti; <br /> 5.Flea#ing and cooifng systems,if insta!!ed at the time of the tesf,sha!!be tumed off;and <br /> 6.8upply and return reglsters,iP installed at the time of the test,shall be fully open. <br /> O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combust(on air. <br /> O R402.4.3 Fenestration air leakagelNindows,skylights and sliding glass doors shall have an air infiltration rate af no more than 0.3 cfm <br /> per square foot('1.5 Us/m2),and swinging doors no mare than 0.5 cfrn per square foot(2.8 L/stm2},when tested according ta NFRC 44Q or <br /> AAMAIWOMAlCSA 10111.5.2IA44Q by an accredited,independent laboratary and lisked and labeled by the manufacturer. <br /> Exception: Site-built windows,skylights and doors. <br /> O F24p2.4.4 Recessed llghting. Recessed luminaires instalied in the bui{ding thermai envelape shall be sealed to limit air leakage <br /> between conditioned and uncpnditioned spaces.All recessed luminaires shali be IC-rated and labeled as having an air leakage rate not <br /> more fhan 2.q cfm(0.944 Us)when tested in accordance wifh ASTM E 283 at a 1.57 psf(75 Pa}pressure differential.AIi recessed <br /> luminaires shaii be sealed with a gaskef or caulk between the housing and the interior wali or ceiling covering. <br /> � R4d3.1.1 Thermostat proulsion(Mandatary).Af Eeasf ane thermostat shall be provided far each separate heafing and cooling system. <br /> � R403.1.3 lieat pump supptementary heat(Mandatory}.Heat pumps having supplementaty e(ectric-resistance heat shati have confrols <br /> that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. <br /> � R403.2.2 Sealing(Mandatoqr}:11!ducts,air handlers,and filter boxes and building cavities that form the primary a1r containment <br /> passageways for air distribution systems shall be considered ducts and p�enum chambers,shaii be constructed and sealed in accordance <br /> with Section C403.2.7.2 of the Commercial Provisians af this code and shall be shown to meet duct tightness criteria by post-construction <br /> ar raugh-in tesking below. <br /> Duet tightness sha!!be vecified by testing to Sectian 803 of the RESNET Standards by either an energy raler certified in accordance with Section <br /> 553.99,Fiarida Statutes,or as autharized by Fiorida Staiutes,to be"substantialty leak free"by either of fhe following: <br /> 1 Post-construction tesl:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area <br /> wfien tested at a pressura differential of 0.1 inches w.g.(25 Pa}across the entire system,including the manufacturer's air handler enc(osure.Ati <br /> register booYs sha!!be taped or otherwise sealed during the fest. <br /> 2. Raugh-in iest:Tota!Eeakage shatf be tess than or equa!ta 4 cfm{113 Umin)per 700 square feet{9.29 m2)of conditioned floor area when fested <br /> at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers sfial�be <br /> taped or othenrrise sealed during the fest.If fhe air handter is nat instatted at the time of the test,total leakage shall be less fhan or equal to 3 cfm <br /> (85 llmin}per 100 square feet(9.29 m2}af condifioned floor area. <br /> Excepiions: <br /> 1. The totaf leakage test is not required for ducts and air handiers located entirely within the building envelope. <br /> 2. Duct testing is not mandatocy for buildings complying by Section R405 af thts code. <br /> 9(7l2017 7:51 AM EnergyGaugeB�USA-FlaRes2(l14 -Section R405.4 1 Com I'age 1 of 3 <br />