Laserfiche WebLink
FORM R405-2094 <br /> � Florida Department of Business and Professional Regulafions <br /> Residentia! Whole Buildin Performance and Prescri tive Methods I <br /> ADDRESS: Permif Number: <br /> Dade City,FL, <br /> � iVIANDATC}RY REQUiREMENTS�ee individual code sections for fu11 details. <br /> E7 401.3 Energy Performance Levet(EPL}dispiay card(Mandatory}, The buitciing officia!sha{!reqvire that an energy perfarmance ievei{EP�} <br /> disptay card be campteted and certified by the builder io be accurate and correct before final approval of the building for occupancy.Florida law <br /> (Section 553.9085,Florida 5tatuesJ requires the EPL display card to be included as an addendum to each sales contract for both presold and <br /> nanpresoid residentiai buildings.The EPL display card confains information indicating the energy per€ormance level and efticiencies of components <br /> instai(ed in a dweEling uniE.The building afficial shall verify that the EPL display card completed and signed by the builder accurately reflects the plans <br /> and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. <br /> � RA02.4 Air leakage(Mandatory). 7he building thermal envelope shall be constructed to(imit air leakage in accordance wifh the requirements of <br /> Sections R402.1 through R402.4.4 <br /> p R402.d.1 Bu3lding thermat envelope, The building thermal envelope shall comply with Sections R402:�3 1 and-R4Q2.-4:1.2.-The <br /> sealing methads between dissimilar materials shall a!!ow for differentia!expansian and contraction. <br /> • EZ402.4.1.1 instatlatian.The components of the building therma!envelope as listed in Table R402.4.1.1 sha!!be installed In <br /> ' accordence with the manufacturer's instructians and the criteria listed in 7able 402.4.1,1,as applicable to the method of construction. <br /> Where required by the code officiai,an approved third party shai!inspecf alI camponents and verify compliance. <br /> • R402.4.1.2 Testing. The buitding or dweiiing unit sha(i be tested and verified as having an air leakage rate of not exceeding 5 air <br /> changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in C(imate Zones 3 khrough 8.Testing shal!be conducted with <br /> ( a blower door at a pressure of 0.2 inches w.g.{50 Pascals).Where required by the code official,testing shall be conducked by an <br /> i approved third party.A written reporl of the resulis of tfie test shali be signed by the party conducting the tesf and provided fa the cade <br /> afficial.Testing shall be performed at any time after creation of aSi penefrations af the building thermai envelope. <br /> During testing: <br /> 1 Exterior windows and daors,fireplace and stove doors sha!!be closed,but not sealed,beyond the intended weatherstripping ar <br /> other infiltration control measures; <br /> 2.C}ampers inciuding exhaust,intake,makeup air,backdraff and flue dampers shali be closed,but nof sealed beyand intended <br /> infiltration contro!measures; <br /> 3.Interior doors,if installed at the time of the test,shall 6e open; <br /> 4.Exterior doors for continuous ventilation sysfems and heaf recovery ventilators sha11 be closed and sealed; <br /> 5.HeaCing and cooling systems,if installed at the time of the test,sha!!be turned off;and <br /> I 6.Supply and retum registers,if installed at the time of the test,shali be fuliy open. <br /> i <br /> O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. <br /> O R402.4.3 Fenestration air leakagelNindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm � <br /> per square foot(1.5 Us/m2},and swinging doors no more than 0.5 cfm per sguare foot(2.8 tlstm2},when tested accarding to NFRC 404 or � <br /> AAMAlWDMFttGSA 109lLS.2lA440 by an accredited,independent labaratory and lisked and labeled by the manufacturer. <br /> Exceptian: Site-built windows,skylights and doors. <br /> O R402.4.4 Recessed tighf3ng. Recessed luminaires instailed in the building therma!envelope shall be sealed to fimit air leakage <br /> between conditioned and uncanditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not <br /> more than 2.q cfm(0.944 Us)when tasted in accordance with ASTM E 283 at a 9.57 psf(75 Pa}pressure differentiat.Ai1 recessed <br /> luminaires shati be sealed wiYh a gasket or cau(k between Ehe housing and the inieriar wall or ceIling covering. <br /> � R4d3.9.1 Thermostat provision(Mandatory}.Af least ane thermostat shali be pravided for each separate heating and caoling system. <br /> � R4d3.1.3 Heat pump sugplemenfary heat(Mandatory}.Neaf pumps having suppiementary electrio-resistance heat shall have controls <br /> thaf,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet ihe heating load. <br /> � R4U3.2.2 SealIng{Mandatory}1A ducts,air handlers,and filter boxes and 6uilding cavities that form the primary air containment <br /> passageways for air distribution systems shall be considered ducts and plenum chambers,sfiail be constructed and seated in accordance <br /> with Section C4d3.2,7.2 of the Cammercla!Pravisions of ihis cade and sha!!be showr�to mee2 duct tightness criteria hy post-construciian <br /> ar raugh-in testing below. <br /> Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section <br />' 553.99,Florida Stafutes,or as authorized 6y�Iorida Statutes,to be"substantiatty leak free"by either of the foltowing: <br /> i 1 post-construction test:Total leakage shall be iess than or equal to 4 cfm(113 Umin}per 100 square feet(9.29 m2}of conditioned floor area <br /> when fested a#a pressure diiierentiai of 4.1 inches w_g.{25 Pa}across the entire system,including the manufacturer's air handSer enclosure.Ati <br /> register boots sha!!be taped or othenvtse sealed during the test. <br /> 2. Rough-in tesk:Totai leakage shal!be less t�an or equa!to 4 cfm{113 Urnin)per 900 square feet(9.29 m2)of conditioned floor area when tested <br /> at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be <br /> taped or othenvise sealed during the test.If the air handter is�ot insta)Ied at the time of the test,totai leaKage shalC be less fhan or equal to 3 cfm <br /> (85 Umin)per 104 sguare feet{9.29 m2)of conditioned floor area. <br /> ExcepUons: <br /> 1. The talal leakage tesi ls not required for ducts and air handlers located entirely withln the bullding envelope. <br /> 2. Duct testing is not mandatory for buildCngs complying by Section R4Q5 of thls code. <br /> 9!7l2017 7:51 AM EnergyGauge(�USA-FlaRes2Q14 -Section R405.4.1 Com Page 1 of 3 <br />