My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19007
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:00:11 PM
Creation date
9/17/2018 2:00:08 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19007
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6772 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect 5umma Job: Ryman B Plex <br /> '��"�" '�►R`������'�" � � Date: Sep p6,201T <br /> Unif 1 By: DJM <br /> • . . . <br /> Far. F2yman 6 Plex <br /> Dade City,FL <br /> No#es: <br /> d - • � o - <br /> Weather. Tampa lnfi AP, FL, t1S <br /> Winter Design Conditions Summer Design Canditior�s <br /> Outside db 43 °F Oufside db g� °F <br /> inside db 70 °F Inside db 75 °F <br /> Design TD 27 °F Design 7D 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisfure difference 54 gdlb <br /> Heating Summary Sensible Caoling Equipment ILoad Sizing <br /> Structure 10083 Btuh Structure 10451 Btuh <br /> Ducts 2317 Btuh Ducts 3367 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> none <br /> (nor�e) <br /> Fiumidificatian 0 Btuh Blower 0 Btuh <br /> Piping 0 BEuh <br /> Equipment load 9240Q 8tuh Use manufacturer's data n <br /> Ratelswing multiplier 0.96 <br /> �r�filtratiora Equipment sensible load 13321 Btuh <br /> Method Simplified Laterat Coating Equipment Load Sizing <br /> Canstrucfion quality Average <br /> Fireplaces 0 Struc#ure 2570 Btuh <br /> Qucts 767 Bfuh <br /> Cenfral vent(0 cfm) 0 Btuh <br /> Neating Goaiing (nane} <br /> Area(ft2} 1108 1108 Equipment latent foad 3337 Btuh <br /> Uolume(f�j 9693 9693 <br /> Air changeslhour p.43 p.23 Equipment Total Laad(Sen+Lat) 1H658 Btuh <br /> Equiv.AVF(cfm} 70 37 Req.tatal capacity at 0.80 SHR 1.4 ton <br /> �ie�tSng Ec�ueprnent Susnrv�ary �c�oling Ec�uiprt�en#Sumrr�ary <br /> Make Nlake Carrier <br /> Trade 5 KW Trade CARRIER AtR CONDI710N(NG <br /> Model Cond 24AC6318ABN32 <br /> AHRI ref Coil FB4CNP018L <br /> ANRI ref 9859025 <br /> Efficiency 10Q EFF Effiiciency 11.5 EER, 14 SEER <br /> Heating input 3.6 kW Sensible caofing 13680 Btuh <br /> Heating output 12409 Btuh Latent cooling 3420 Btuh <br /> "femperafure rise 20 °F Tata!cooling 171QQ Btuh <br /> Actual air flaw 57Q cfm Actua!air fiow 570 cfm <br /> Air fiow factar Q.446 cEmlBtuh Air flaw factor 0.041 cfmlBtuh <br /> Static pressure 4.53 in H20 Static pressure 0.53 in H20 <br /> Space fhermastat Load sensible heat ratio 0.89 <br /> Caicuiations approved by ACCA to meet alt requirements of Manual J 8th Ed. <br /> �q,/pf �y�+-„��}{�' 2�97-Sep-0708:16:11 <br /> � Ri9hlSuiteB Unlversal 201717.0.23 RSU11p33 Pa9e� <br /> 1$"�� .Google Drivel0ocumentslSonny'slRyman 6 Plex.rup Caic=MJB Froni 600r faces: E , <br /> 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.