Laserfiche WebLink
FORM R405-2014 <br /> PROJECT <br /> Title: Ryman 6 Plex Bedrooms: 12 Address Type: Street Address <br /> Building Type: User Conditioned Area: 6576 Lot# <br /> Owner: Ryman 6 Plex Total Stories: 1 Block/SubDivision: <br /> #of Units: 1 Worst Case: No PlatBook: <br /> Builder Name: Rotate Angle: 0 Street: <br /> Permit Office: Pasco Cross Ventilation: No County: Pasco <br /> Jurisdiction: Whole House Fan: No City,State,Zip: Dade City, <br /> Family Type: Multi-family FL, <br /> NewlExisting: New(From Plans) <br /> Comment: <br /> CLIMATE <br /> / IECC Design Temp Int Design Temp Heating Design Daily Temp <br /> V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range <br /> FL,Tampa FL_TAMPA INTERNATI 2 39 91 70 75 645.5 54 Medium <br /> BLOCKS <br /> Number Name Area Volume <br /> 1 Blockl 6576 52608 <br /> SPACES <br /> Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated <br /> 1 Main 6576 52608 Yes 12 12 1 Yes Yes Yes <br /> FLOORS <br /> # Floor Type Space Perimeter R-Value Area Tile Wood Carpet <br /> 1 Slab-On-Grade Edge Insulatio Main 346 ft 0 6576 ft' 0 0 1 <br /> ROOF <br /> / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch <br /> V # Type Materials Area Area Color Absor Tested Tested Insul. (deg) <br /> 1 Hip Composition shingles 6930 ft' 0 ft' Medium 0.9 N 0.9 No 0 18.4 <br /> ATTIC - <br /> V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC <br /> 1 Full attic Vented 300 6576 ftZ Y N <br /> CEILING <br /> # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type <br /> 1 Under Attic(Vented) Main 30 Blown 6576 ft' 0.1 Wood <br /> 9/7/2017 7:49 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Soflware Page 2 of 4 <br />