My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
17-19008
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:01:29 PM
Creation date
9/17/2018 2:01:25 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19008
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6762 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U <br /> �= Pro ect Summa Job: Ryman 6 Plex <br /> ���g���i��� V/I/t s � Byte: DJM 6,201T <br /> ' � � • <br /> For: Ryman 6 Plex <br /> Dade City, FL <br /> Notes: <br /> � - • • • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br />� Outside db 43 °F Outside db 91 °F <br /> Inside db 70 °F Inside db 75 °F <br /> Design TD 27 °F Design TD 16 °F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/Ib <br />, Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10083 Btuh Structure 10451 Btuh <br /> Ducts 2317 Btuh Ducts 3367 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12400 Btuh Use manufacturer's data n <br /> Rate/swing multiplier 0.96 <br /> Infiltration Equipment sensible load 13321 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2570 Btuh <br /> Ducts 767 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ftz) 1108 1108 Equipment latent load 3337 Btuh <br /> Volume(fN) 9693 9693 <br /> Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh <br /> Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Make Carrier <br /> � Trade 5 KW Trade CARRIER AIR CONDITIONING <br /> . Model Cond 24ACB318ABN32 <br /> AHRI ref Coil FB4CNP018L <br /> AHRI ref 9859025 <br /> Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 3.6 kW Sensible cooling 13680 Btuh <br /> Heating output 12409 Btuh Latent cooling 3420 Btuh <br /> Temperature rise 20 °F Total cooling 17100 Btuh <br /> Actual air flow 570 cfm Actual air flow 570 cfm <br /> Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfMBtuh <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 <br /> Space thermostat , Load sensible heat ratio 0.81 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I <br /> �- ��� ����,�" 2017-Sep-07 08:16:11 <br /> �1,+� � � Right-Suite�Unlversal 2017 17.0.23 RSU11033 Page 6 <br /> `�%�r�'+ ..Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MJB Front Door faces: E <br />