Laserfiche WebLink
FORM R4Q5-2014 ' _ �. <br /> FLt3RIDA ENERGY EFFICIENCY C{JDE FOR BUlLD1�G CC)NSTRUCTIC}N <br /> Flarida Department of Business and Professional Regula�ion - Residentia! Performance Method <br /> Projecf Name: Ryman 8 Plex Bailder Name: <br /> Street: Permit Office: Pasco <br /> City,State,Zip: Dade City,FL, Permit Number: <br /> Owner: Ryman 8 Flex Jurisdiction: <br /> Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. WaIl7ypes(4628.d sqfE.) {nsutation Area <br /> ---2-8ingie-family-or-m�ltiple-(ar�ily Multi=family a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft2 <br /> Tb.- r�me=11Vood,-Adjacenf-�-�--�R=�£"�l;4"-1512:OQ-ftZ <br /> 3. Number of units,if multiple famiiy 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms �2 d.N/A R= ft� <br /> � 90.Geiling Types {6576.0 sqft.) Insulafion Area <br /> 5. Is this a worst case7 No a.Under Attic(Vented) R=30.0 6576.00 ft' <br /> 6. Conditioned Raor area above grade{ftz) 6876 b.N/A R= ft' <br /> Conditioned floor area below grade(ftz) 0 �'�tA � �Z <br /> 11.Ducts R ft' <br /> 7. Windows(522.0 sqft.} Description Area a.Sup:Attic,Ret:Attic,AH:Garege 6 200 <br /> a. U-Facfor; Dbl,U=0.3d 522.00 ft2 <br /> SHGC: SHGC=0.26 <br /> b. U-Factor: NIA ft' 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: a Cantral Unit 106.2 SEER:14.00 <br /> c. U-Factor. N/A ftx <br /> SHGC� 13.Heating systems kBtWhr Effciency <br /> d. U-Factor� N/A ft2 a.Electric Strip Heat 1Q6.2 COP:1.00 <br /> SNGC: <br /> Area Weighted Average Overhang Depth: 1.000 ft. <br /> Area Weighted Average SHGC: 0.260 14.Hot water systems <br /> a.Electric Gap:40 gallons <br /> $. Floar Types (6576.0 sqft.} lnsulatian Area ' <br /> a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 EF.a.95a <br /> b. Conservatian features <br /> b.NCA R= n2 (�o�e <br /> c.N/A �- �2 18.Credits Psfat <br /> Tatai Propased Madified Loads: 166.75 ���+�v , <br /> Glass/F(oor Area: 0.079 � ���� <br /> � Total Baseline Loads: 170.26 <br /> s <br /> � <br />, I hereby certify that the pl�s ar�d pecifications covered by Review of the plans and Q�'C1���T.qT� <br />, this calculation are in comptiance�'th the Flarida Energy specificafions covered by this _�' ,,f� «^�ti,p�, <br /> Code. „I � � calculation indicates compliance y'`�rArr��; '� .��.� � <br />, '! 1� � with the Florida Energy Code. � ur„�����::�'%�,�;:,�,`°„ O <br />, PREPARED BY: '1 Sefore construction is completed � � �'F:�,�.r.. � <br /> pqT�; this buifding wi(t be inspecfed for � - ���`' ' ,a� <br /> � �r §��;� <br /> compliance with Section 553.908 * �, u <br /> i hereby certify that this building, as designed, is in compliance Florida Sfatutes. .t,�,, ��, <br /> with the Florida Energy Code. �D{�'�'C�'� <br /> OWNERiAGENT: BUILDWG O F'iC1 : <br /> DATE: DATE: " � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.2.2.1. <br /> -Comptiance requires an Air Barrier and Insulation Inspection Checklist in accardance wlth R402.4.1.1 and an envelope leakage <br /> test report in accordance with R402.4.1.2. <br /> - Gamptiance with a proposed duct leakage Qn requires a Duct Leakage Test Repoct confirming duct leakage to outdaars, <br /> tested in accordance with Secfion 803 of RESNET Sfandards,is not greater than 0.030 Qn for whote house. <br /> 91712017 7:49 AM EnergyGauge�USA-FlaRes2Q'!4 Section R405.4.1 Gampliant Soflware Page i of 4 <br />