17-19010
Zephyrhills
>
Building Department
>
Permits
>
2017
>
17-19010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/17/2018 2:02:57 PM
Creation date
9/17/2018 2:02:55 PM
Metadata
Fields
Template:
Building Department
Company Name
DRIFTWOOD
Building Department - Doc Type
Permit
Permit #
17-19010
Building Department - Name
RYMAN CONSTRUCTION INC
Address
6754 BASSWOOD CIRCLE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> � �ra ect Sumrna Job: Ryman 6 Ptex <br /> �" �'V�1��'1E��L��" j � Date: Sep O6,Zo�� <br /> Unit 3 By: OJM <br /> i • 0 M <br /> Far. Ryman 6 Plex <br /> Dade City,FL <br /> Nates: <br /> � ! - • . e <br /> Weather: Tampa Intl AP, FL, US <br /> � Winter Design Conditians Summer Design Gonditions <br /> Outside db 43 "F Outside db 93 °F <br /> (nside db 7Q °F lnside db 75 °F <br /> Qesign TD 27 °F Design TD 16 °F <br /> Raily range L <br /> Relative humidity • 50 % <br /> Moisture difference 54 grllb <br /> Heating Summary Sensible Caoling Equipment Laaci Sizing <br /> Structure 6111 Btuh Sfructure 8327 Sfuh <br /> Ducts 2331 Btuh Ducts 3390 Btuh <br /> Central vent(0 cfm} 0 Bfuh Centra)vent(0 cfm} 0 Btuh <br /> none <br /> (none} <br /> Humidification 0 Btuh Biawer 0 Btuh <br /> Piping 0 Btuh <br /> Equipment(oad 8442 SEuh Use manufacture�s clata n <br /> Rate/swing multiplier 0.96 <br /> , �tt�liti'atioil Equipment sensible load 11295 Btuh <br /> Method simplitied Latent Cooling Equipment Load Sizing <br /> Cons#ruction quality Average <br /> Fireplaces 0 Structure 1846 Btuh <br /> Ducfs 814 Btuh <br /> Central vent(Q cfm) 0 Btuh <br /> Heating Cooting {none <br /> Area(ft2) '1090 1090 Equipmenf iate�t load 2660 Bfuh <br /> Vo(ume(fi�) 9693 9693 <br /> Air changes/hour 0.20 0.13 Equipment To#a!Load(Sen+Lat) 93955 Btuh <br /> Equiv.AVF(cfm} 33 18 Req.toYal capacity at 0.70 SHR 1.3 tan <br /> He��ir�g E�uepr�ee�t Sumrnary �oalin� Eq�ipm�n#�ummary <br /> Make Make Carrier <br /> Trade 5 KW Trade CARRIER AIR CONDITIONING <br /> Made! Cond 24ACB318ABN32 <br /> AHRI ref Coil FB4CNP018L <br /> AHRI ref 9859025 <br /> E�ciency 100 EFF Efficiency 11.5 EER, 14 SEER <br /> Heating input 2.5 kW Sensible cooling 11970 Btuh <br /> Heafing oufput 8448 Btuh �atent cooling 5130 Btuh <br /> Temperature rise 13 °F Total caaling 97100 8tuh <br /> Actual air flow 570 cfm Actua!air flaw 570 cfm <br /> Air f(ow factor 0.068 cfmlBtuh Air flow factor 0.449 cfm/Btuh <br /> Static pressure 0.53 in H20 Static pressure 0.53 in H20 <br /> Space thermostat l.oad sensible heak�atio 0.89 <br /> Catculations approved by ACCA fo meet al1 requirernents of Manual J 8th Ed. <br /> '*�'� � �����fi����p Rlght-Suitefa�Unlversa1201717.0.23 RSU11033 2017-Sep-0708:16:11 <br /> .�% }�...Google DrivelDocumentslSanny'slRyman 6 Plex.rup Calc=MJB Fronl Door faces: E <br /> Page 3 <br />