Laserfiche WebLink
ro ' T � <br /> ` • • <br /> t� Duct System Summary Job: Ryman 6 Plex <br /> � ��`��CL�J�O�� Date: Sep O6,2017 <br /> VI1If s By: DJM <br /> ' � � � <br /> For: Ryman 6 Plex <br /> Dade City, FL <br /> Heating Cooling <br /> External static pressure 0.53 in H20 0.53 in H20 <br /> Pressure losses 0 in H20 0 in H20 <br /> Available static pressure 0.53 in H20 0.53 in H20 <br /> Supply/return available pressure 0.392/0.138 in H20 0.392/0.138 in H20 <br /> Lowest friction rate 0.415 in/100ft 0.415 in/100ft <br /> Actual air flow 570 cfm 570 cfm <br /> Total effective length(TEL) 128 ft <br /> � � � - . e <br /> Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv <br /> Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk <br /> Unit 6 8alh 1 c 134 3 6 0.489 4.0 Ox 0 VIFx 10.0 70.0 <br /> unit s eath 2 h 412 19 16 0.522 4.0 Ox 0 VIFX 5.0 70.0 � <br /> UniI6 Bed 1 c 2319 92 96 0.433 6.0 OX 0 VIFx 20.4 70.0 <br /> unit s sed z h 3580 165 110 0.415 8.0 OX 0 VIFx 24.4 70.0 <br /> uni�s Kitchen C 2321 57 96 0.477 6.0 Ox 0 VIFX 12.0 70.0 ( <br /> unit s�iviny c 3000 117 124 0.502 7.0 OX 0 VIFX 8.1 70.0 <br /> Unft 6 Living-A C 3000 117 124 0.477 7.0 Ox 0 VIFx 12.0 70.0 i <br /> I <br /> o � � � <br /> I <br /> i <br /> Grille Htg Cfg TEL Design Veloc Diam H x W Stud/Joist Duct ' <br /> Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk � <br /> ( <br /> rb7 Ox 0 570 570 33.3 0.415 533 14 0 Ox 0 VIFx rst48 � <br /> � <br /> e . I <br /> Trunk Htg Clg Design Veloc Diam H x W Duct I <br /> Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk I <br /> rst48 Peak AVF 570 570 0.415 533 14.0 0 x 0 VinlFlx � <br /> , j <br /> I <br /> � <br /> I <br /> I <br /> h 2017-Sep-07 08:16:11 j <br /> �J. � �1��y�����tl Right-Suile�Universal 201717.0.23 RSU11033 Page 6 � <br /> ��i .Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MJB Front Door faces: E � <br /> I <br /> I <br /> � <br />