Laserfiche WebLink
Single Family D�welling <br /> P1an Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2. Lots shali be graded to comply with R401.3 af the F.B.C. <br /> 3. Compaction test required if 24" or more of fill dirt is braught in at any one place. <br /> 4. Tie in survey required before pouring cancrete. <br /> 5. L?riveways require a R.O.W. use permit. A114 sides af driveway thru the sidewalk shall have <br /> expansion rnaterial. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and tnarked at tirne of first inspection. <br /> 8. All A.D.A. requirements shall be met. <br /> 9. No elecfiric,plumbing, lnechanical, or framin�shall be cavered withaut an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separatian). <br /> 11. Appliances shall nat be installed in a locatian where subject to mechanical damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12. Watex heaters sha11 comply with sectian P647.3 of the F.B.C. <br /> 13. Foundation supparts far A/C units shall be raised at least 3" above finished grade. M1308.1 <br /> 14. Return air in all bedroazns. F.B.C, M1624.4 <br /> 15. Smoke detectors are ta be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B.Cr <br /> 17. All means of egress are to be in accordance with R311 ofthe F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combinatian-type AFCI breakers are required at a111ocations requiring an AFCI type breaker. <br /> 20. Carban monoxide alarms will be required in new consfizction that uses fossil-burning heating <br /> ar appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 22. A112Q08 N.E.C. Codes will be enforced. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 <br /> 24. In accordance with the Land Develapment Cade, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> Z5.A eopv of the ener��-v cacls shatl be with permit ut all tintes <br /> 26. Copv of Fnal insulation report shall be provided with pern:it before finaZ <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 5�Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008) <br />